OverviewIndoor dual-technology Grade 2 sensor with rotatable lens for 15m (50ft) wide detection or 24m (80ft) narrow detection
Key features- Hardwired indoor Grade 2 dual technology (PIR + microwave) with rotatable lens
- Wide detection up to 15 m, 85° (PIR) / Narrow detection up to 24 m (PIR only)
- Double conductive shielding for visible light / RFI protection
- Variable high mount 2.0 - 3.0 metres
Product seriesPart of the FlipX Professional Series, the FLX-P-DT is OPTEX's latest Grade 2 indoor sensor featuring an innovative pyro sensor with human catch element and OPTEX patented double conductive shielding for high-detection performance. The rotatable lens allows switching between wide and narrow detection modes. With OPTEX Tough MOD TM Technology, the FLX-P-DT is designed for durable microwave module performance in hot and humid climates, suitable for commercial and professional applications.
Features (detailed)- Dual technology: Combines microwave and PIR detection; alarm is triggered only when both layers are activated. Incorporates Tough MOD to prevent corrosion from condensation, humidity and damage due to lights or temperature changes.
- Spherical lens design: Specially designed spherical lens provides a precise focal length of each detection ray onto the pyroelectric elements to ensure consistency throughout the detection field and reduce missed alarms.
- Easy installation: Viewable multi-colour LED indicator, removable 180° cover lock, and EOL resistor socket for simple installation.
ApplicationsDownloads (available documents)- FlipX Professional Manual
- FlipX Professional Datasheet
Technical specifications- Product Range: FlipX Series
- Model Code: FLX-P-DT
- Detection method: Passive infrared & Microwave
- Detection Coverage: Wide: 15 m (50 ft.) 85° / Narrow: 24 m (80 ft.) 5° (No microwave detection at Narrow setting)
- Power input: 9.5 to 16 VDC
- Current draw: 11 mA (normal), 14 mA (max.) at 12 VDC
- Alarm period: 2.0 ± 0.5 s
- Warm-up period: Approx. 60 s (LED blinks)
- Alarm output (R): N.C. 24 V DC 0.1 A max. (resistive load)
- Trouble output: N.C. 24 V DC 0.1 A max. (resistive load) — open when the cover is removed
- Tamper output: N.C. 24 V DC 0.1 A max. (resistive load) — open when the cover is removed
- LED indicator: Green — [1] Warm-up [2] Alarm
- Operation temperature: -20°C to +45°C (-4°F to +113°F)
- Relative humidity: 95% RH max.
- Installation method (indoor/outdoor): Indoor
- Mounting height: 2.0 to 3.0 m (6'7" to 9'8")
- Weight: 110 g (3.88 oz)