Three-phase switchgear KYN28A-24
ACmedium-voltagevacuum

Three-phase switchgear - KYN28A-24 - SAIP ELECTRIC GROUP CO.,LTD - AC / medium-voltage / vacuum
Three-phase switchgear - KYN28A-24 - SAIP ELECTRIC GROUP CO.,LTD - AC / medium-voltage / vacuum
Three-phase switchgear - KYN28A-24 - SAIP ELECTRIC GROUP CO.,LTD - AC / medium-voltage / vacuum - image - 2
Add to favorites
Compare this product

Characteristics

Electrical characteristics
medium-voltage, AC, three-phase
Configuration
metal-clad, vacuum
Applications
for electrical networks, power distribution
Other characteristics
modular, draw-out
Primary current

Min.: 630 A

Max.: 4,000 A

VAC

Min.: 3,600 V

Max.: 24,000 V

Description

Product overview
Armoured withdrawable metal-enclosed AC switchgear KYN28A-24(Z)(GZS1) for three-phase 50 Hz power systems. Designed for reception and distribution of electrical energy and for control, protection and monitoring of circuits. Complies with standards GB3906-2006, GB/T11022, IEC60298 and DL/T404.

Model code
  • Indicates installation of a vacuum circuit breaker
  • Rated voltage (kV)
  • Design number
  • Indoor use
  • Withdrawable (draw-out) design
  • Armoured / metal-enclosed


Environmental conditions (normal use)
  • Ambient temperature: max +40°C, min -15°C
  • Humidity: daily average relative humidity ≤95% (daily vapor pressure ≤2.2 kPa); monthly average ≤90% (monthly vapor pressure ≤1.8 kPa)
  • Altitude: ≤1000 m
  • Earthquake intensity: ≤8 degrees
  • Atmosphere free from significant corrosive/flammable gases, excessive water vapor or dust; no frequent severe vibration


Key technical parameters
  • Rated voltage: 3.6, 7.2, 12, 24 kV
  • Rated frequency: 50 Hz
  • Circuit breaker rated current options: 630, 1250, 1600, 2000, 2500, 3150, 4000 A
  • Switchgear rated current: 630–4000 A (same options)
  • Rated short-time withstand current (4 s): 16, 20, 25, 31.5, 40, 50 kA
  • Rated peak withstand / making current (peak): up to 40–100 kA depending on configuration
  • Insulation/withstand levels (examples): power-frequency 1 min: 24/32/42/65 kV; lightning impulse (peak): 40/60/75/125 kV
  • Protection level: cabinet shell IP4X (door/chariot area IP4X when opened)


Structure and features
  • Fully metal-armoured, assembled structure with flexible combination schemes
  • Cabinet body made of aluminium-zinc coated thin steel plate with multi-fold processing and blind rivet nut/high-strength bolt connections for precision and interchangeability
  • Supports VS1-24 series or VD4 series vacuum circuit breakers for wide applicability and low-maintenance operation
  • Withdrawable handcart with work and test positions; each position fitted with positioning and indication devices
  • Modular, interchangeable handcarts across identical specifications
  • Earthing switch options: front-mounted (center) for two-sided maintenance or rear-mounted to save wall space
  • Current transformer installation in rear cable compartment or hoisted at bottom of large curved plate
  • Cable compartment accepts up to 9 single-core cables
  • Each high-voltage chamber includes a pressure-relief channel and reliable interlocking meeting five-prevention safety requirements
  • Front and rear doors with observation windows for visual inspection


Main components
  • Busbar room
  • Circuit breaker handcart room
  • Cable room
  • Relay / instrument room
  • Shell, branch bus, bus bushing, main bus, static contact device, contact box, current transformer, earthing switch, cable, lightning arrester, ground bus, loading/unloading partitions, pressure relief device, control wire duct, etc.


Dimensions (selected)
  • Height B: 2430 mm
  • Height A: 1000 mm (for branch bus rated current ≤1250 A or ≥1600 A as applicable)
  • Height C: 1810 mm (cable ingress/egress) or 2170 mm (overhead incoming/outgoing)
  • Typical cabinet width A: 1000 mm; cabinet depth C: 1500 mm (cable) or 2170 mm (overhead)


Ordering information
  • Provide main circuit diagram number, purpose and single-line diagram, rated voltage/current, rated short-circuit breaking current, distribution room layout and switchgear arrangement
  • Specify control, measurement and protection functions and interlock/automation requirements
  • Specify model, specification and quantity of main electrical components
  • If busbar bridges are required, provide rated current capacity, span, height from ground and related data
  • Detail any special environmental conditions or other requirements


Technical specifications
  • Model: KYN28A-24
  • Rated voltage: 3.6, 7.2, 12, 24 kV
  • Rated frequency: 50 Hz
  • Circuit breaker/switchgear rated currents: 630, 1250, 1600, 2000, 2500, 3150, 4000 A
  • Short-time withstand (4 s): 16–50 kA (depending on version)
  • Breaking/making peak currents: up to 40–100 kA depending on configuration
  • Insulation and lightning impulse levels: multiple stages per configuration
  • Protection: cabinet shell IP4X