video corpo
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

Power distribution substation YBM29
for medium-voltage transformerscompactprefabricated

Power distribution substation - YBM29 - SAIP ELECTRIC GROUP CO.,LTD - for medium-voltage transformers / compact / prefabricated
Power distribution substation - YBM29 - SAIP ELECTRIC GROUP CO.,LTD - for medium-voltage transformers / compact / prefabricated
Add to favorites
Compare this product

Characteristics

Fonction
power distribution, for medium-voltage transformers
Options and accessories
prefabricated, compact, outdoor
Rated voltage

Max.: 12,000 V

Min.: 400 V

Current

Max.: 3,000 A

Min.: 100 A

Description

Product description
YBM, YBP (ZBW) series box-type prefabricated combined transformer substations integrate high-voltage switchgear, transformer(s) and low-voltage switchgear into a compact, complete power distribution unit for receiving and distributing electricity in urban high-rise buildings, residential communities, parks, industrial and high‑tech zones, small and medium factories, mines, oilfields and temporary construction sites. The unit has a three-compartment layout (high-voltage room, transformer room, low-voltage room), small footprint and is designed to reduce civil works compared with conventional substations. It is suitable for ring network distribution, dual-source supply or terminal (radial) systems and complies with GB 17467-2010 SD320.

Normal use environmental conditions
  • Altitude: up to 1000 m
  • Ambient temperature: -25°C to +40°C (24 h average ≤ +35°C)
  • Wind speed: ≤ 35 m/s
  • Air relative humidity and site: normal installation conditions; no conductive dust or corrosive/flammable/explosive substances harmful to metals or insulation
  • Seismic and installation: horizontal acceleration within design limits; no severe vibration; installation slope ≤ 3°


Main technical parameters
Rated high-voltage: 7.2/12 kV. Transformer secondary voltages: 6/0.410/0.4 kV. Rated transformer capacity: selectable, examples 50–1250 kVA per unit; combined arrangement up to 2×1250 kVA. Typical HV rated current 200–630 A; LV up to 100–3000 A depending on configuration. Short-time withstand, peak and making currents depend on configuration (examples: 20*(2) kA, 12.5*(4) kA, 31.5/63 kA). Power-frequency and lightning impulse withstand values specified per equipment. Noise: oil-immersed <55 dB; dry type <65 dB. Protection class: shell typically IP54. Dimensions vary with selected switchgear and transformer; example YBM29 1250 kVA L 5000 B 3000 H 2980.

Structural features
The unit is divided into three functional compartments: high-voltage room, transformer room and low-voltage room. HV and LV rooms are fully functional; HV side can be arranged for ring network, terminal or dual supply and fitted with HV metering components. Transformer options include low-loss oil-immersed types (S9, S11, SCB10, SCB13) and dry-type transformers. The transformer room is equipped with forced‑air cooling and lighting; a temperature controller can automatically regulate transformer temperature. The top cover is double-layer thermal insulation with ventilation eaves for convection. The base uses a sectional steel frame. Shell materials and finishes are selectable (non‑metallic, ordinary steel, stainless steel, aluminum alloy, color steel composite) with outdoor anti‑corrosion, waterproofing and dust protection. Cable in/out wiring is standard; other wiring methods available on request.

Plane layout and dimensions
Refer to the plane layout diagram on the product page. Typical dimensions (examples): YBM29 100–250 kVA L 3000 B 2000 H 2520 A 3320 C 2320; YBM29 315–630 kVA L 4000 B 2600 H 2560 A 4320 C 2920; YBM29 800–1000 kVA L 4600 B 2600 H 2560 A 4920 C 2920; YBM29 1250 kVA L 5000 B 3000 H 2980 A 5320 C 3320. YBP29 dimensions depend on the low‑voltage outlet arrangement.

Characteristics / technical specifications
  • Series / model family: YBM, YBP
  • Standards: GB 17467-2010 SD320 (box-type substations)
  • Rated HV voltage (Ue): 7.2 / 12 kV
  • Transformer secondary voltages: 6 / 0.410 / 0.4 kV
  • Rated capacity (Se): selectable up to 1250 kVA per unit; combined up to 2×1250 kVA
  • Rated currents and short-circuit characteristics: depend on configuration (examples in table)
  • Power-frequency and lightning withstand values: specified per equipment
  • Noise level: oil-immersed <55 dB; dry type <65 dB
  • Protection class: typically IP54
  • Cooling & ventilation: natural and forced ventilation; transformer room with forced‑air cooling and automatic temperature control
  • Structure and materials: three-compartment layout; selectable shell materials and surface treatments

Other SAIP ELECTRIC GROUP CO.,LTD products

Power Distribution System

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry