Characteristics

Type
diaphragm
Operation
electric
Body
flange, threaded
Applications
for fire safety applications
Associated function
fire protection
Other characteristics
remote control, deluge
DN

Max.: 200 mm
(7.874 in)

Min.: 40 mm
(1.575 in)

Pressure

Max.: 20.7 bar
(300.2 psi)

Min.: 1.4 bar
(20.3 psi)

Description

Overview
The DV-5A deluge valve features a diaphragm-style design with external resetting capability, allowing system reset without opening a valve handhole to reposition a clapper or latch. Properly pretrimmed, the valve's double-seat arrangement enables fire alarm actuation upon system operation. Available actuation options include wet, dry and electric, with remote-reset and remote-reset/pressure-reducing variants.

General
System and Actuation Type: Deluge (Wet, Dry, Electric)
Listings and Approvals: UL and C-UL Listed; FM, VdS, LPCB Approved (see technical data sheet for model-specific approvals)
Sizes: 1-1/2-inch to 8-inch (DN40 to DN200)

Features
  • External reset without accessing valve internals
  • Diaphragm single-moving-part design for simplified maintenance
  • Offered pretrimmed or as valve and trim components sold separately
  • Multiple approved configurations — refer to technical data sheet for listings

Benefits
  • Reduced valve room footprint through streamlined trim options
  • High pressure rating and low pressure drop improve hydraulic performance over distance
  • Range of actuation types and remote-reset options support diverse system requirements
  • Simplified trim layout eases installation and servicing

Technical specifications
  • Connection Type: Grooved x Grooved, Flange x Flange, Flange x Grooved, Thread x Thread NPT
  • Pressure Rating: Valve: 20 to 300 psi (1.4 to 20.7 bar); Trim: see technical data sheet
  • Sizes: 1-1/2-inch to 8-inch (DN40 to DN200)
  • System and Actuation Type: Deluge (Wet, Dry, Electric)
  • Listings and Approvals: UL and C-UL Listed; FM, VdS, LPCB Approved (see technical data sheet)
  • Design highlights: Diaphragm single-moving-part construction; double-seat design provides fire alarm actuation when trimmed appropriately
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.