The CP 400 /420 Dual Sensor Pressure Calibrator provides unmatched pressure measurement flexibility with 0.025%FS accuracy on both internal,isolated,stainless steel pressure sensors. An external pressure module connection supports all BetaPort -P pressure modules for even greater measurement capability. A Pt100 RTD input is provided for temperature measurements accurate to 0.1°C (0.2 °F).In addition,the CP 400 /420 measures 4-20 mA loop current and up to 30 VDC.
|
|
PC6 IDOS Pressure Calibrator
combines the latest developments in pressure instrumentation with advanced sensor and component technology to offer a versatile calibration instrument.
The PC6 IDOS is supplied with our hand held test systems:
LTP1 Low Pressure pneumatic test system -27 inHg vacuum to 45 psi (-900 mbar to 3 bar)
TP1 Pneumatic pressure test system -27 inHg vacuum to 600 psi (-900 mbar to 40 bar)
HTP1 Hydraulic pressure test systems to 10,000 psi (700 bar)
Intecal for Industry compatible
Features & Benefits:
It is designed for accurately testing and calibrating the following types of instruments:
Pressure Transducers / Transmitters
Pressure Switches / Relief Valves
Pressure Indicators (analogue / digital)
Process Indicators
Current / Voltage to Pressure Converters
|
|
|
|
|
|
The DPI 880 is a lightweight and simple to use hand-held instrument that provides high accuracy measurement of electrical, temperature, pressure and flow parameters from a single device. The DPI 880 measures and sources milliamps, millivolts, volts, ohms, frequency, thermocouples, RTDs, pulses and pressure; captures switch values; and provides 24 volt loop power. Ultra-compact and convenient, the DPI 880 is a powerful tool for testing, configuring and calibrating virtually any process parameter. Dual readings of both input and output parameters simplify calibration and system diagnostics.
The DPI 880 shares common features with the other DPI 800 Series models including a large, bright, backlit display for easy reading in all lighting conditions, rubberized exterior for durability and ruggedness, intuitive menu system for ease of use, Hart® loop resistor, and Intelligent Digital Output Sensor (IDOS?) port for use with remote pressure modules.
?With the DPI 880, we?ve rolled the capabilities of the entire DPI 800 Series line-up into a single device,? said Jim Henke, product manager for GE?s sensing business. ?In spite of the DPI 880?s extensive functionality, we?ve retained the compact design, intuitive operation, and high accuracy levels that our customers require. ?
|
|
Electronic Pressure Calibrator as precision reference instrument for pressure comparison calibration purposes:
Ranges: mbar-ranges up to +4000 bar
Gauge Pressure, Absolute Pressure, Vacuum
Accuracy up to ±0.025% FS
For portable or stationary use.
- Type LDM70-K50: Accuracy ±0.5% FS
- Type LDM70-E25: Accuracy ±0.25% FS
- Type TLDMM-A02: Accuracy ±0.2% FS
- Type TLDMM-A01: Accuracy ±0.1% FS
- Type TLDMM: Accuracy ±0.05% FS
- Type LPC 300: Accuracy ±0.025% FS
- Type LPC 200: Accuracy ±0.025% FS or 0.1% of reading
- Type PC4: lowl presure (mbar-ranges)
|
|
MEP-DC, the SCANDURA portable pressure calibrator, is the perfect solution for the calibration of every pressure device: transducers, manometers, transmitters, converters and switches.
The main features of this calibrator are:
• display of the reference pressure value and the related measurement unit
• maximum pressure value during the measurement process
• leakage indication in a pressure circuit
• current an voltage measurement
• switch status indication
• vacuum and pressure generation up to 21 bar
MEP-DC can feed a supply loop at 24 V d.c. Through a PDA (with a PalmOS™ sw) it manages the complete calibration cycle till the printing of the reports.
|
|
We help you, if you are under pressure!
A suitable pressure calibrator for any application
Pneumatic and hydraulic pressure calibrators of series PM... and PC... distinguish themselves especially by high accuracy of measurement and compact type of construction.
The calibrators are used in the field or laboratory, production and service for inspection or calibration of pressure sensors,
gauges, pressure switches and by-pass valves. Reference pressures of -1 up to 700 bar can be generated in a fast and simple way.
|
|
Applications:
- National institutes and institutions
- Research and development laboratories
- Industry (laboratory, workshop and production)
- Calibration service companies
Special Features:
- Up to 4 sensors can be integrated
- Pressure ranges: from 0 ... 100 mbar to 0 ... 2500 bar
- Total uncertainty of measurement: 0.025 % ... 0.008 % (certified)
- Over pressure safety (up to 400 bar)
- Easy retrofitting
Remarks:
- modular up to 4 Sensors (different types)
- can be easily retrofitted (module concept)
- optional with barometric reference
- calibration software EasyCal available
|
|
Portable calibration device KAL 100/200with integrated pressure generator. Measurement ranges from 0 - 100 Pa to 0 - 100 kPa.
Combination pressure transducer and pressure gauge. The desired pressure is set by digital input. No need to connect to an external pressure generator
The KAL 100/200 calibration device, a combination pressure transducer and pressure gauge, can be used to test and calibrate pressure sensors and other low-pressure gauges.
The desired pressure is set by digital input, and pressure is generated quickly and precisely through the use of a closed loop, thereby eliminating the need for an external pressure generator.
With RS 232 serial interface. Easy-to-operate calibration device
with an excellent price/performance ratio.Medium: Air, all inert gases
|
|
|
The FlowAnalyser PF-300, PF-301 VAC & PF-302 LOW are highly accurate testing devices, which bi-directionally measure flow, pressure, temperature, humidity and O2 concentrations.
|
|
|
|
|
|
Type ATE-100 Handheld LCD Digital Calibrator - Pressure, Temperature, Voltage and Current Measurement
-Interchangeable pressure and temperature modules
-Pressure measurement accuracies of ±0.025, 0.05 and 0.10%, or .06/.07%
-Pressure ranges from 0.25 in.H2O to 10,000 psi
-Supports most standard RTD probes and thermocouples
-Min./max., tare, flow, leak, programmable damping, percent function, trip detect, all standard
-High static dP measurement capability
Optional:
FM Approval for Class I, Div. 1, Groups A, B, C & D hazardous areas Datalogging, Hi/Low alarm relays
The Ashcroft® ATE-100 is a calibration system with a vast array of capabilities. These capabilities extend far beyond those of precision pressure measurement. The base unit contains a wide variety of application-specific firmware as well as the ability to measure both current and voltage inputs. In addition, this unit has the ability to interface the system with a computer, data acquisition system or dumb terminal via the standard RS232 interface.
|
|
|
|
|
|
These Pressure Calibrators from KELLER are very precise calibration instruments for the calibration of pressure transmitters, pressure switches and pressure gauges.
The Low- and Medium ranges are pneumatic, and the High ranges are hydraulic. The portable housing incorporates the pressure generating pump, a high precision reference sensor and the measuring electronics.
The transmitter under test is connected to the pressure port of the calibrator and the signal is read out directly on the display. Various internal functions and performance features assist the user in many different measuring tasks. In addition, the serial interface allows the transfer of the measured data onto a PC for further processing. The calibrator, including accessories, is supplied with a robust carrying case and is ideal for outdoor, on-site use.
To meet differing requirements, two basic versions of the calibrator are offered:
Full-Version
The Full-Version of the calibrator is a complete, self-contained transmitter testing unit. With internal supplies for the transmitter and the calibrator itself, the self-contained instrument is always ready for use. For a variety of measuring and testing tasks, a wide selection of software functions are incorporated:
MANO
displays the pressure and the maximum and minimum pressures
MANO (with transmitter connected)
displays the pressure, the transmitter signal and the temperature
HOLD
freezes the actual measured values on the display
|
|
A Pitot Static tester is a pressure generator and pressure measurement instrument which can simulate altitude and speed of aircraft on-board equipments.
Flying conditions need to be simulated on on-board equipments when they are manufactured, repaired, or integrated to the aircraft.
ATEQ-OMICRON has developed two kinds of Pitot Static testers:
• For workshop to test on-board instruments when they are manufactured, repaired or calibrated.
• For hangar or tarmac to verify instrument directly on aircraft.
|
|
ADTS 505 Compact, portable Air Data Test Set
The ADTS 505 is a precision twin-channel Ps and Pt pressure control test set for the accurate calibration/verification of civil aircraft pitot statistics.
Compliant with RVSM (Reduced Vertical Separation Minimal) requirements
Features:
- High accuracy – RVSM compliant
- Fully automatic control
- Rugged flightline construction
- Wide ranging aircraft compatibility
- Integral pneumatic supplies
- Protection for aircraft instruments
|
|
| ... products without technical information |
| |
|
|