Fresh air is sucked in via an intake hood.
The filter section consists of an extractable filter with a V-type filter mat of quality class EU4. The intake side is fitted with a louvered damper with oppositely coupled profiled slats and a rod assembly for mechanical actuation. The unit is prepared for the addition of a damper servomotor.
The fan section consists of a double-active radial fan made of galvanized steel. The impellor is statically and dynamically balanced; the bearings of the shaft are durable low-noise roller bearings. The driving motor is a three-phase motor with V-belt. It is supported together with the fan by a diagonal support or a base frame free of vibrations.
|
|
| ... products without technical information |
| |
... see all the products in the category
Axial fans
|
Spiral housing fan VREB 600°C/120min.
Centrifugal fan, single inlet with backward curved blades, specific speed nq = 90; 100.
Sizes:
VREB 355 - VREB 1.400 (Ømm)
Application:
Smoke exhaustion up to 600°C/120min.
Technical Data:
V = 1.000 - 80.000 m³/h
P = 300 - 3.000 Pa
L = 0,25 - 75 kW
|
|
Designed to meet exacting air quality standards, the Type K Exhauster maintains high efficiency over a wide range of operations. Rugged and effective, the Type K Exhauster wheels are designed for years of trouble free operation. The Type K incorporates a heavy gage all-welded housing construction with a unique winged rib design. On the shaft, the split taper hub is an exclusive AAF feature that prevents impellers from freezing to shafts.
Available in 14 sizes ranging from 7-inch to 42-inch inlet diameters, the Type K Exhauster is available in standard AMCA arrangements 1 and 9. Arrangement One is predominantly used for the usual industrial exhaust system. Where space is a premium, Arragement Nine should be considered. Other constructions include corrosion resistant coatings, special alloy steels, spark resistance, and high temperature units. Accessories such as fan housing drains, flanges, and a shaft seal may also be included.
|
|
General description :
Simple aspiration centrifugal fan in die-cast aluminium (RAL 3000 red painting) and impellor with radial blades welded in high thickness steel suitable for the transport of even very dusty air . The characteristics of low flow rate and high pressure allow a large use in centralized gas exhaust extraction system (reels, aluminium ducts…) in Automotive sector thanks also to its resistance to high temperatures (up to 100°C) and no spark version. Noise level: the level noise values have been measured in free field (ISO 3744 standards). In environments with low level noise, it is recommended to use silencers and /or sound-proof boxes.
ACCESSORIES
• Pedestal
• Shaped inlet
• Anti-vibration connection
• Sound proof box
• Silencers
|
|
A central fan for more than one extraction arm
The FAN 55 and 80 are designed for central installations serving several extraction arms. In most cases, local fans are preferred. However, there are applications where a central fan is better. The FAN 55 can be used as a central fan for 3 to 4 arms and the FAN 80 for 4 to 6 arms.
|
|
|
This essential component to carry outside warm combustion smoke from pellet fireplaces, is driven by an high-performance external rotor fans, enable to maintain long-life operational stability. The fan offers fair silence and the tachometer to control fan speed.
|
|
|
PlymoVent's TEV-series fans are design to be used as central fans. These fans are equipped with a light weight aluminium impellers, suited to exhaust gases, volatile fumes and dust. Matched inlet and outlet areas provide, together with the optimized impellers, an even air flow, higher capacity and lower noise level.
|
|
CV MANN 400ºC
MMVC 20/20 - MMVC 30/28
DESCRIPTION:
Smoke emergency fans 400ºC/2h according to EN 12101-3:2002 European standard.
Airflow: 13.000 - 54.000 m3/h
APPLICATIONS:
- Industrial use.
- Industrial and professional cooking.
- Smoke emergency exhaust.
|
|
|
The SERIE EP centrifugal electrical fans with simple inlet are especially suited to applications where it is necessary to feed clean air at temperatures up to 100°C. They are produced in painted steel.
|
|
|
very high efficiency centrifugal fan for heavy flow rates at medium-high pressure. Fan wheelwith backward inclined vanes, suitable for dusty air.Max. air temperature: 60°C; with cooling fan: 300°C. Special constructions upon request.
|
|
Paxton's Fume Exhausters and Vacuum Producers provide a reliable, non-pulsating source of air / fume vacuum which is ideally suited for applications such as:
- Flat Sheet Hold-Down
- Air Monitoring & Sampling
- Pneumatic Conveying
- Suction Pick-Up
- Tank Exhaust Systems for Brewing or Storage
- Textile / Fabric Cutting Systems
- Bag or Package Filling
- Transfer of Air or Gases
- Process Air
- Fume Exhauster
- And Many Others
|
|
Centrifugal fan VDVB 600°C/120min.
Multiple garage fan unit, smoke exhaust design, direct drive, for roof installation.
Sizes:
VDVB 355 - VDVB 1.250 (Ømm)
Application:
Smoke exhaustion at 700°C/120min
Technical Data:
V = 500 - 90.000 m³/h
P = 200 - 2.800 Pa
L = 0,25 - 55 kW
|
|
|
The SERIE ET roof centrifugal fans are especially suited to applications where it is necessary to suck clean air or fumes at temperatures up to 70°C. The base is produced in steel. The fan dome is produced in plastic reinforced by fiber glass.
|
|
Smoke Extract Roof Fans F400 (400°C / 120 min.)
vertikal outlet
operation of tested smoke extraction motor (EN 12101-3)
Diameter of impeller: 355-710mm
max. V= 28.100 m³/h
max. pt= 1.650 Pa
smoke and heat extraction unit (double function)
many accessories
Application:
main air extraction for residences, offices and industry
|
|
| ... products without technical information |
| |
|
|