The first self-testing obstacle warning light
The new range of TWINY obstacle warning lights is made of a master and a slave beacons. The "slave" is automatically working as soon as the "master" is down. This design is securing the obstacle beaconing, since the system will be permanently operational. The Twiny range also includes a dimmer switch which will automatically switch on and off the lights during day and night time.
Furthermore, the TWINY range has a unique and specific self testing device, working daily or on request according to customer specifications. The test procedure check the two beacons conditions. If ever one of the light test is negative, a defect contact will report the information. The testing procedure is visible from the ground (no need to reach the beacons to start or witness the test).
Three types of low intensity obstacle warning lights are available within the TWINY range: the BA10 incandescent lights, the LED BA15 lights as well as the Neon BA20 and BA30 types.
|
|
Round Wire
For use in lightning protection and earth-termination systems according to DIN EN 50164-2 (VDE 0185 Part 202).
|
|
|
|
|
|
Even small overvoltages can disable sensitive electronic equipment, computer networks and computer-controlled production systems in fractions of a second. For protection against overvoltages which can result from lightning or switching processes in electrical supply networks, OBO offers a wide range of surge and lightning arresters for the German and international markets. These include not only devices to protect AC networks of various voltage levels, but also special systems for data lines and telecommunication devices, and protective modules for process measurement and control systems.
With the new LightningControllern, OBO presents innovative lightning protection systems with patented multi-carbon technology in the new VBS catalogue. The first modular spark gap for perfect integration into distribution systems. The great advantage of the new units is that they have a fully encapsulated housing. This means no more arcing! This eliminates the risk of fires in the distribution box due to sparking.
The OBO range of systems for external and internal lightning protection is also complete. All components have passed the tests imposed by the Lightning Protection and EMC Technology Centre in Menden and have the corresponding test marks and certificates.
|
|
* Coordinated spark-gap-based lightning current arrester, consisting of a base part and plug-in protection module
* Maximum system availability due to RADAX Flow follow current limitation
* No tripping of 32 A gL/gG fuses up to short-circuit currents of 50 kArms
* Discharge capacity up to 50 kA (10/350 µs)
* Directly coordinated with DEHNguard surge protective devices without additional cable length
* Low voltage protection level
* Operating state/fault indication by mark in the inspection window
* Allows for easy replacement of protection modules due to module locking system with releasing button
|
|
|
The quarter wave stub devices feature best in class performance specifications, including bi-directional protection, low VSWR, normal and reverse polarity, high RF power and ultra low let through(5V). Using robust materials in construction the maintenance free quarter wave serier is ruggedized, weatherproof to IP68 standard.
|
|
| ... products without technical information |
| |
|
|
|
|
The first self-testing obstacle warning light
The new range of TWINY obstacle warning lights is made of a master and a slave beacons. The "slave" is automatically working as soon as the "master" is down. This design is securing the obstacle beaconing, since the system will be permanently operational. The Twiny range also includes a dimmer switch which will automatically switch on and off the lights during day and night time.
Furthermore, the TWINY range has a unique and specific self testing device, working daily or on request according to customer specifications. The test procedure check the two beacons conditions. If ever one of the light test is negative, a defect contact will report the information. The testing procedure is visible from the ground (no need to reach the beacons to start or witness the test).
Three types of low intensity obstacle warning lights are available within the TWINY range: the BA10 incandescent lights, the LED BA15 lights as well as the Neon BA20 and BA30 types.
|
|
Round Wire
For use in lightning protection and earth-termination systems according to DIN EN 50164-2 (VDE 0185 Part 202).
|
|
| ... products without technical information |
| |
|
|
|
|
Even small overvoltages can disable sensitive electronic equipment, computer networks and computer-controlled production systems in fractions of a second. For protection against overvoltages which can result from lightning or switching processes in electrical supply networks, OBO offers a wide range of surge and lightning arresters for the German and international markets. These include not only devices to protect AC networks of various voltage levels, but also special systems for data lines and telecommunication devices, and protective modules for process measurement and control systems.
With the new LightningControllern, OBO presents innovative lightning protection systems with patented multi-carbon technology in the new VBS catalogue. The first modular spark gap for perfect integration into distribution systems. The great advantage of the new units is that they have a fully encapsulated housing. This means no more arcing! This eliminates the risk of fires in the distribution box due to sparking.
The OBO range of systems for external and internal lightning protection is also complete. All components have passed the tests imposed by the Lightning Protection and EMC Technology Centre in Menden and have the corresponding test marks and certificates.
|
|
* Coordinated spark-gap-based lightning current arrester, consisting of a base part and plug-in protection module
* Maximum system availability due to RADAX Flow follow current limitation
* No tripping of 32 A gL/gG fuses up to short-circuit currents of 50 kArms
* Discharge capacity up to 50 kA (10/350 µs)
* Directly coordinated with DEHNguard surge protective devices without additional cable length
* Low voltage protection level
* Operating state/fault indication by mark in the inspection window
* Allows for easy replacement of protection modules due to module locking system with releasing button
|
|
|
The quarter wave stub devices feature best in class performance specifications, including bi-directional protection, low VSWR, normal and reverse polarity, high RF power and ultra low let through(5V). Using robust materials in construction the maintenance free quarter wave serier is ruggedized, weatherproof to IP68 standard.
|
|
|
|
|
|
Multi-Differential Relay – MDR-2 – digital speed and accuracy, maximum reliability
The MDR-2 is a differential current relay intended for protection of a generator against internal short circuits (leaking currents). It is based on a 16-bit digital signal processor providing maximum performance and reliability.
Features include
> Response time 50 ms
> 3-phase detection of current on primary and secondary side of the generator
> Active, adjustable compensation of non-balanced current measurements
> Measuring accuracy 1%
> Stress-free configuration and operation via clear and simple menu structure
> DIN-rail or base-mounting with remote mountable display
> Approved according to LR, GL, etc.
All measured and calculated values are shown in clear text and numbers on the large LCD display (allowing significant savings on purchase and wiring of external meters).
Available options include a block (generator + step-up transformer) protection option and a short-circuit and overcurrent protection option.
DEIF's utility software for setup, monitoring and control is free of charge
Available software download for this product click here
|
|
The voltage protection relay REU 610 is part of the RE_ 610 series of numerical relays for the protection and supervision of utility substations, and industrial switchgear and equipment.
The voltage protection relay is primary designed for the overvoltage protection of power system components, such as busbars, feeders, power transformers and capacitor batteries. The relay is also used for general power system earth-fault supervision. Further, the relay can be used for undervoltage protection of motors and overvoltage protection of capacitor batteries, for initialization of automatic busbar changeover, and for disconnecting small power units from the network in cases of network disturbance.
The voltage protection relay REU 610 supports a wide range of standard communication protocols, among them the IEC 61850, IEC 60870-5-103, Modbus, Profibus and DNP.
|
|
The A-ISOMETER® of the IR420 series is designed to monitor the insulation resistance of AC control circuits (IT systems) 0...300 V. If the systems to be monitored include DC components, such as switched-mode power supplies or solenoid valves, the display and operating characteristics may be affected.
The display and response values apply to pure AC systems. An external supply voltage allows de-energized systems to be monitored too.
|
|
SIPROTEC 7RW600 is a numerical, multifunction relay for connection to voltage transformers. It can be used in distribution systems, on transformers and for electrical machines. If it detects any deviation from the permitted voltage, frequency or overexcitation values, it responds according to the values set.
SIPROTEC 7RW600 can be used for the purposes of system decoupling and for load shedding if ever there is a risk of a system collapse as a result of inadmissibly large frequency drops. Voltage and frequency thresholds can also be monitored.
This voltage, frequency and overexcitation relay can be used to protect generators and transformers in the event of defective voltage control, of defective frequency control, or of full load rejection, or furthermore islanding generation systems.
|
|
The Voltage Protection Relay (VPR-A) has been designed to measure the line or phase RMS voltages under normal conditions or under disturbances. This information is internally processed by the microprocessor, to take the voltage protection actions defined under ANSI or IEC standards. The different functions provided by the VPR-A may be classified into the following groups:
Applications:
* Protection of generators, motors and transformers against adverse system voltage conditions.
* Supervision of automatic transfer switching schemes.
Protection:
* Selection of protection curves a definite time.
* Timed and instantaneous undervoltage (ANSI 27t/27i).
* Residual undervoltage (ANSI 27r).
* Timed and instantaneous overvoltage (ANSI 59t/59i).
* Homopolar overvoltage (ANSI 59N).
* Voltage unbalance (ANSI 46).
* Overfrequency and underfrequency (ANSI 81).
* Phase reversal (ANSI 47).
* Five (5) output relay programmable.
* Loss of control volts relay.
|
|
| ... products without technical information |
| |
SecureLinx -Surge Protection for Security Products
Premiere Surge Protection for all your Security, CCTV, Access Control and Alarm applications
|
|
Weidmüller develops, produces and sells high-quality overvoltage protection and has established this field as its core line of business over the years. Our objective is always first and foremost to fulfil our customers’ application requirements. With our know-how, we have developed a programme which combines reliable overvoltage protection with affordable solutions: in low-voltage power supplies, I&C technology, telecommunication and industrial data processing.
|
|
|
Raychem Gas Discharge Tubes (GDTs) are commonly used to help protect sensitive telecom equipment such as power lines, communication lines, signal lines and data transmission lines from damage caused by transient surge voltages that typically result from lightning strikes and equipment switching operations.
|
|
| ... products without technical information |
| |
| ... products without technical information |
| |
Surge Protection Devices (SPD) are also known as Transient Voltage Surge Suppressors (TVSS). These devices can comprise a complex arrangement of varistors, transorb diodes and gas arresters. The function is to divert lightning surge energy away from electrical or electronic equipment. They are activated by the steep voltage impulse generated by a lightning strike and are designed to conduct tens of thousands of Amps in impulse energy. Typical impulse tests for SPD devices include energy absortion (8/20us or 10/350us), duty cycle (8/20us), Clamping voltage (8/20us) and Combination Wave Tests for devices connected in the AC power main.
EMC PARTNER offer a range of instruments from a few Amps up to 100,000 Amps.
All units offer a combination of impulses specific for particular devices whether they are disc varistors, SMD varistors, Gas Arresters or combinations of all.
|
|
|
These devices are designed to help protect sensitive telecommunication equipment from the hazards caused by overvoltage faults stemming from lightning, power contact, and power induction. They have a high electrical surge capability to help protect against transient faults and a high off-state impedance, rendering them virtually transparent during normal system operation.
|
|
|
Raychem%u2019s PolySwitch devices are used to help protect against harmful overcurrent surges, and overtemperature faults. Like traditional fuses, these devices limit the flow of dangerously high current during fault conditions. The PolySwitch device, however, resets after the fault is cleared and power to the circuit is removed, thereby reducing warranty, service and repair costs.
|
|
Tyco Electronics offers among the widest selection of surface-mount fuses available for addressing a broad range of overcurrent protection applications. Helping to prevent costly damage and promote a safe environment for electronic and electrical equipment, Raychem chip fuses provide performance stability to support applications with current ratings from .5ADC up to 20ADC.
Tyco Electronics also offers the Raychem telecom FT600 fuse for telecommunications applications. This telecom fuse helps comply with North American overcurrent protection requirements, including Telcordia, GR-1089, TIA-968-A (formerly FCC Part 68), and UL60950 3rd edition.
|
|
|
|