- Electricity - Electronics >
- Energy: Production and Distribution >
- Medium-voltage switchgear >
- Tianan
Tianan medium-voltage switchgear
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 630 A - 5,000 A
VAC: 220 V
VDC: 110, 220 V
... KYN28A‑12
Rated
voltage: 12 kV
Rated frequency: 50/60 Hz
1 min power‑frequency withstand
voltage (phase‑to‑phase): 42/48 kV
Lightning impulse withstand
voltage: 75/85 kV
Auxiliary circuit ...
Ningbo Tianan (Group) CO.,Ltd.
Primary current: 1,250 A - 1,250 A
VAC: 220 V
VDC: 48, 110, 220 V
... protection:
HV compartment IP67;
LV compartment IP4X. Cabinet outline (single): 500 × 885 × 2060 mm; common cabinet example 465 × 885 × 2060 mm; up to 6 common boxes, width increment 465 mm.
Main switch parameters ...
Ningbo Tianan (Group) CO.,Ltd.
Primary current: 630, 1,250 A
VAC: 12 kV
... Standards
- IEC60694 — Common specifications for high-voltage switchgear and control gear
- IEC62271-100 — AC circuit breakers
- IEC62271-200 — Metal-enclosed AC switchgear (1
Ningbo Tianan (Group) CO.,Ltd.
Primary current: 125, 1,250, 630 A
VAC: 220 V
VDC: 220, 110 V
... General
The XGN (XGTD6)-12(24) indoor gas‑insulated metal‑enclosed
switchgear is a
medium‑voltage SF6‑insulated assembly designed for secondary distribution and compact substation applications. It features a ...
Ningbo Tianan (Group) CO.,Ltd.
Primary current: 630 A - 2,500 A
VAC: 220 V
VDC: 110, 220 V
... A)
Auxiliary/control
voltage — DC110/220, AC220 V
Rated working pressure of insulation gas (20°C) — nominal 0.05 MPa; minimum 0.03 MPa
Annual gas loss rate — ≤ 5 ‰
Degree of protection —
HV gas compartment ...
Ningbo Tianan (Group) CO.,Ltd.
Primary current: 630 A - 3,150 A
VAC: 220 V
VDC: 110, 220 V
... >
Ningbo Tianan (Group) CO.,Ltd.
Primary current: 630 A - 3,150 A
VAC: 220 V
VDC: 220, 110 V
... General
KYN61-40.5 is an air‑insulated withdrawable metal‑clad
switchgear designed for 40.5 kV three‑phase AC single‑busbar, single‑section systems. It is intended for power distribution, control, protection and monitoring in ...
Ningbo Tianan (Group) CO.,Ltd.
Primary current: 630, 1,250 A
VAC: 12 kV
... /li>
Ningbo Tianan (Group) CO.,Ltd.
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.