Fan motors rotate fans to cool the inside of PCs and other office automation (OA) equipment by directing heat outside. Minebea Motor Manufacturing Corporation manufactures high-end fan motors with Minebea ball bearings, and fan motors with long-life sleeve bearings.
|
|
Fan motors
Copal has developed silent compact fans with low vibration and high air capacity, thanks to proprietary impeller and frame design. Fan motors operate in car navigation systems, digital video cameras, etc.
|
|
|
The SERIE EP-AP-D centrifugal electrical fans with simple inlet are especially suited to applications where it is necessary to feed clean air at temperatures up to 60°C. Removable fan-motor unit; they are equipped with a protective grid and double protective carters. They are produced in painted steel.
|
|
|
|
|
|
MF Series Cross Flow Fans (8)
Cross flow fans create a wide flow of air using a long cylindrical-shaped impeller. Air is drawn inn along the sides of the runner, flows along the circumference of the runner, and is blown out laterally, creating a uniform flow of air. Cross flow fans are used for cooling circuit boards installed in equipment, air curtains, and other applications. In addition, cross flow fans offer the advantages of right-angle air flow and rectangular shape which facilitates installation in corners and saves space.
AC Input
MFD Series Cross Flow Fans (16)
Cross flow fans create a wide flow of air using a long cylindrical-shaped impeller. Air is drawn inn along the sides of the runner, flows along the circumference of the runner, and is blown out laterally, creating a uniform flow of air. Cross flow fans are used for cooling circuit boards installed in equipment, air curtains, and other applications. In addition, cross flow fans offer the advantages of right-angle air flow and rectangular shape which facilitates installation in corners and saves space.
DC Input
|
|
Mounting size for AC-input: 80mm - 250mm
Mounting size for DC-input: 42mm - 119mm
Air capacity 0.18m³/min - 24m³/min
Static pressure 12Pa - 360Pa
AC-input: 200/220/230V AC or 100/110/115V AC
DC-input: 12V DC or 24V DC
Marking: CE, UL and cUL
Long-life type also available (MDE-Series).
|
|
|
|
|
|
MRS Series Axial Flow Fans (34)
Axial flow fans use a propeller to create a flow of air in the direction of the axis of rotation. Because they create a large airflow, axial flow fans are optimal for a wide variety of cooling and other airflow needs.
- High-Efficiency, Low-Noise Models
- AC Input
- Frame sizes from 5.51 in to 9.84 in
- Maximum airflow from 177 CFM to 883 CFM
- RoHS compliant models available
MU Series Axial Flow Fans (16)
Axial flow fans use a propeller to create a flow of air in the direction of the axis of rotation. Because they create a large airflow, axial flow fans are optimal for a wide variety of cooling and other airflow needs.
- Slim-Line, General Purpose Models
- AC Input
- Frame sizes from 3.15 in to 4.69 in
- Maximum airflow from 19.4 CFM to 106 CFM
MDE Series Axial Flow Fans (2)
Axial flow fans use a propeller to create a flow of air in the direction of the axis of rotation. Because they create a large airflow, axial flow fans are optimal for a wide variety of cooling and other airflow needs.
- Long-Life Models (up to 100,000 hours)
- DC Input
- 4.69 in frame size
- 95.3 CFM maximum airflow
MDS/MD Series Axial Flow Fans (48)
Axial flow fans use a propeller to create a flow of air in the direction of the axis of rotation. Because they create a large airflow, axial flow fans are optimal for a wide variety of cooling and other airflow needs.
- High-Performance Models
- DC Input
- Frame sizes from 1.65 in to 6.77 in
- Maximum airflow from 4.59 CFM to 212 CFM
- RoHS compliant models available
|
|
... see all the products in the category
Axial fans
|
GE ASD Inverter Duty:
Designed for use in blowers, fans, pumps, conveyors, material handling, compressors, and other inverter duty appliccations.
Features and Benefits:
- Standard Features
- Infinity:1 CT Speed Range CH to 90 Hz
- IGBT Compatible
- N/C thermostat
- Opp DE mounting face & stub shaft for tach mounting
- C-Face foot mount thru 30 HP
- Cast Iron Frame & Brackets
- Class F Insulation
- 440 Fr have insulated ODE brg/Grd brush
|
|
Series: K2.. 90 to 355
Output range: 0.25 kW to 500 kW
Class: 3,000; 1,500; 1,000; 750 rpm, lower speeds and pole-changeable versions on request
Features: Energy-efficient and environment-friendly, suitable for frequency converter supply, designed to DIN EN 60034 (IEC 72) and pr EN 12101-3, mounting dimensions and assignment of output ratings to DIN 42673, 42677 or progressive, robust low-vibration grey-cast iron design, versions for jet fans without shaft-mounted fan or pad-mounted, robust low-vibration grey-cast iron design, degree of protection IP 55, higher degrees up to IP 65 on request, class F insulation with thermal reserve, class H and higher possible, various modifications available
|
|
|
|
|
|
Applications
These smoke removal systems are applied in a broad range of applications including large buildings, shopping malls, factories, warehouses, enclosed parking lots, tunnels, among others. In other words, they are used where a large concentration of people in commercial and industrial facilities is present.
Standard Features
Output: 0.12 up to 355kW
Multivoltage - (220-240/380-415//440-460V or 380-415/660-690//440-460V)
Ventilation Motor, TEAO
Cast iron frames (80 up to 355M/L)
Pad Mounted (frames 80 up to 250S/M)
Mounting: B3L (frame 280S/M and above)
Degree of Protection: IP55
Flying leads 1 meter long
Squirrel cage rotor/Aluminium die cast
Stainless steel nameplate AISI 316
Class "F" insulation
Continuous duty - S1 (S2 - 200°C/2h once only)
Ambient temperature: 40°C , 1000 m.a.s.l.
Regreasing nipples from frame 225S/M and above
Thermistors (1 per phase) fitted in frame 160M and above
Paint color: Silver
Optional Features
Single voltage (other voltages)
Degree of Protection: IP56, IP65 or IP66
Other mounting configurations
Terminal Box
Self Ventilated, TEFC
Thermal protection:
Thermistors for frame 132S and below (Standard for frame 160 and above)
Thermostats
RTD-PT 100
Space heaters
Class "H" insulation
Roller bearings for frame 160M and above
|
|
| ... products without technical information |
| |
|
Exhaust Gas Extraction Units: Wall-hanger units, Mobile units, Roller Units, Exhaust gas spiral hoses, Hose holders, Spiral hose clamps, Exhaust nozzles, Exhaust smoke aspirators.
|
|
The Series M geared motor has been developed with many years of design proficiency which results in a series of speed reducing geared motors offering high load carrying capacity, high efficiency, quiet running and reliability.
Product Specification:
Series M in line geared motors and reducers can meet a wide range of engineering demands offering a very efficient and compact drive solution offering input power up to 90Kw and a maximum output torque capacity of 11,000 Nm.
- Unit Sizes: 01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 13, 14
- Input Power: Up to 90kW (121HP)
- Output Torque: Up to 11,000Nm (97,350 lb.in)
- Gear Ratios: 1.2 to 8:1 single reduction, 1.4 to 70:1 double reduction, up to 250:1 triple reduction 16,200:1 in combined units
- Motor Sizes: IEC Frames from 63 to 280; NEMA Frames from 56 to 405
|
|
Series C Right angle helical worm geared motors and reducers provide a highly efficient and compact solution to meet most requirements up to 45 kW with maximum output torque capacity of 10,000Nm.
Product Specification:
The Series C product adds to the growing family of new drives which has taken advantage of our many years of accumulated design expertise, together with the use of high quality materials and components. The end result is a series of speed reducing and geared motors offering high load carrying capacity, increased efficiency, quiet running and reliability.
- Unit Sizes: 03, 04, 05, 06, 07, 08, 09, 10
- Input Power: Up to 45kW (60HP)
- Output Torque: Up to 10,000Nm (88,500 lb.in)
- Gear Ratios: From 8:1 to 250:1 in a double unit and 60,000:1 in combined units
- Motor Sizes: IEC Frames from 63 to 225; NEMA Frames from 56 to 326
|
|
The units are also available with rubber torque bushes, output flanges, output shafts and KIBO® sleeves to allow for trouble free maintenance. All variants can be fitted with standard IEC motors. Input shaft assemblies are available up to and including F10.
* Unit Sizes: 02,03,04,05,06,07,08,09,10,11,12
* Input Power: Up to 110kW (147HP)
* Output Torque: Up to 16,500Nm (146,000 lb.in)
* Gear Ratios: From 5:1 to 100:1 in double reduction form and in combined unit form up to 5,600:1.
* Motor Sizes: IEC Frames from 63 to 225
|
|
The Series K geared motor is designed with integral cast feet for base or end mounting and can be offered with single or double extended output shafts. Units are also available shaft mounted or with output flanges and are available for mounting horizontally or vertically. The units can also be offered with a bolt on torque reaction bracket and all variants are available either motorised or with an input shaft assembly.
* Unit Sizes: 03, 04, 05, 06, 07, 08, 09, 10 and 12
* Input Power: Up to 90 kW (121 HP)
* Output Torque: Up to 12,300 Nm (109,000 lb.in.)
* Gear Ratios: Up to 160:1 in three stages, 10,000:1 in five stages, and 36,000:1 in six stages
* Motor Sizes: IEC Frames from 63 to 280; NEMA Frames from 56 to 405
|
|
Northland offers a line of Centrifugal Blowers utilizing either our Universal
or Brushless DC motor technology. Our multistage blowers are designed
to operate in up to 120 in H2O (300 mBar) with 0 flow, and up to 220 CFM (100L / sec) at open flow.
|
|
MB Series Centrifugal Blowers (15)
Centrifugal blowers move air by means of the centrifugal force generated by rotating a cylindrical runner on which blades have been arranged. Centrifugal blowers have a small outlet, which concentrates air in a single direction, and are therefore suitable for local cooling. They also create large static pressure, making them optimal for cooling equipment through which air cannot flow easily and for airflow through ducts.
- AC Input
MBD Series Centrifugal Blowers (11)
Centrifugal blowers move air by means of the centrifugal force generated by rotating a cylindrical runner on which blades have been arranged. Centrifugal blowers have a small outlet, which concentrates air in a single direction, and are therefore suitable for local cooling. They also create large static pressure, making them optimal for cooling equipment through which air cannot flow easily and for airflow through ducts.
- DC Input
|
|
Northland offers some of the highest quality vacuum motors on the market,
our Universal (120 - 240 VAC Input) motors based on our popular Round K,
Square K, and B-style laminations. These cost effective blowers typically
include customer specific lead terminations, and mounting details.
|
|
... see all the products in the category
Blowers
|
|
|