- Detection - Measurement >
- Electrical Measurements >
- Calibrator
Calibrators
Temperature: -20 °C - 50 °C
Pressure: 700 bar
Voltage: 25 V
The HPC50 handheld pressure calibrator is an intrinsically safe, dual pressure calibrator with options to add an additional two external pressure or temperature modules. The HPC50 pressure calibrator ...
Crystal Engineering
Temperature: -20 °C - 50 °C
Pressure: 1,000 bar
Voltage: 24 V
The HPC40 Series handheld pressure calibrator is the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -20 to 50°C. You can count on the same accuracy whether ...
Crystal Engineering
Pressure: 0 psi - 5,000 psi
Calibration tool box in the palm of your hand! The 30 Series is a wide range digital pressure calibrator that fits easily into your shirt pocket. Its internal sensors give you 0.05% of reading accuracy and resist damage ...
Crystal Engineering
Temperature: -10 °C - 50 °C
Pressure: 350 mbar - 1,000,000 mbar
Voltage: 200 mV - 30,000 mV
Druck's DPI610E Pressure calibrator The iconic Druck is back! The latest addition to the DPI600 Series is available now Built on a legacy of excellence When Druck launched the DPI610 series pressure calibrator ...
Druck
Temperature: -10 °C - 50 °C
Pressure: 25 mbar - 1,000,000 mbar
Voltage: 4 V
... multifunction calibration tools. Druck multifunction calibrators provide an all-in-one solution for your pressure measurement and generation needs. Our latest DPI 620 Genii multifunction process calibrator ...
Druck
Temperature: 0 °C - 50 °C
Pressure: -0.9 bar - 20 bar
Voltage: 15 V
... the new PV624 with the market leading DPI620 GENii multifunction calibrator and a PM620 pressure module creates a uniquely capable, flexible, self-contained portable pressure calibrator. If you are ...
Druck
Temperature: 0 °C - 50 °C
Multifunction calibrator DC V-A OHM RTD TC Frequency Pressure Mechanical properties Dimensions 206 x 97 x 60 mm Operating conditions Operating temperature 0° ...50° Storage temperature 0° ...50°C El. ...
Orbit Merret s.r.o.
Temperature: -10 °C - 50 °C
Multifunction calibrator DC V Ohm RTD TC Power supply Power supply dvě 1,5 V alkalické baterie Current draw cca 60 mA/3 V Mechanical properties Dimensions 180 x 90 47 mm (s plastovým ochranným ...
Orbit Merret s.r.o.
Temperature: 0 °C - 50 °C
Multifunction calibrator DC V TC Power supply dvě 1,5 V alkalické baterie Mechanical properties Dimensions 180 x 90 47 mm (s plastovým ochranným obalem) Operating conditions Operating temperature 0° ...
Orbit Merret s.r.o.
Radio Influence Voltage (RIV) measurement calibrator Reliable partial discharge testing on transformers Our RIV1 calibrator is used for the calibration of high-voltage partial discharge (PD) test ...
Measuring force - 240 N Max. perm. errors - ± (1,5 + L/100) µm, L in mm Repeatability - 1 µm Resolution - 0,001 mm Power supply - 100 ÷ 240 AC, 1,5 A, 50 ÷ 60 Hz Included in delivery - Declaration of conformity Data output(s) - ...
For comparative and direct measurements • Direct measurement of gauge blocks with a variation in nominal length of up to 25 mm or 1 in. – Enables the number of reference gauge blocks required to be reduced by nearly 80 %. • Comparative ...
For comparative measurements • Measures gauge blocks of same nominal length by comparison. • Comes with the new template system for positioning the gauge blocks. • Single or dual template system for optimum ease of gauge handling. • ...
Fully-automatic measuring dials and precision display testing device for analogue and digital measuring dials, as well as all types of measuring probes with a measuring range of up to 100mm. The measuring results are even more precise ...
The UMP3 is especially suitable for quick and reliable calibration of analogue and digital dial gauges. By its motorized 30 mm precision transducer a dial gauge can be calibrated simple and safe in a trice. Testing of: • Analogue ...
MT30 is a complete product package for checks in both lathes, milling machines as well as turning and machine center. Features STREVEL™ To check that the machine’s movements run straight without any pitch and roll, a solution with ...
MT20 is a complete product package for checks in horizontal lathes / turning centers. Features QUICK INSTALLATION No settings, no adjustments of lasers, no control of centre WIRELESS Enable rotating the machine spindle during ...
Level is a battery-powered measuring sensor that connects wirelessly via Bluetooth to the NXA Ultimate or NXA Pro display unit. Features DUAL-AXIS Measures the angular deviations from the surface in two axes RANGE Large measurement ...
Capacitive Displacement Calibration Stands Capacitec customers have the option of performing calibrations in house or sending the system back to Capacitec for factory recalibration. Recalibration every 12-24 months is typical, depending ...
Voltage: 0 V - 1,000 V
Multifunction calibrator 9010 is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like multimeters, clamp meters, ohm meters, power meters and power analysers, ...
Meatest spol. s r.o.
Voltage: 0 V - 1,050 V
Multifunction calibrator 9010+ is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like 6½ digit multimeters, clamp meters, ohm meters, power meters and power ...
Meatest spol. s r.o.
Voltage: 0 V - 1,000 V
... range from 10 Ω to 100 MΩ. The calibrator offers TC temperature sensor simulation. It can be delivered optionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the calibrator ...
Meatest spol. s r.o.
The CS 2890 Power Calibrator/Simulator is a handheld multifunctional four-phase instrument designed for calibrating and adjusting Metrel power quality Class A and Class S analysers as well as simulation of typical voltage ...
Voltage: 50 V - 300 V
The MI 2891 Power Simulator is a multi-purpose three phase power simulator for simulating typical situations in low voltage power supply systems. It is an excellent tool for training, demonstration purposes, or as an electrical didactic ...
... Accuracy: ±0.003% +5 µV Temperature Calibrator Resolution: 0.01 ⁰ 10X Battery Life – Temperature Calibrator Features Simultaneous Source/Measure MIL-STD Durability ISO 17025 is Included Thermocouple ...
Industrial Thermocouple Calibrator The only multi-thermocouple handheld calibrators made in the U.S.A. that offer superior accuracy for 14 thermocouples, 500–hour battery life, and a 3–year warranty. The ...
Temperature: 5 °C - 45 °C
Voltage: 9 V - 28 V
Introduction Engine RPM Sensor Based on Vibration and Noise Gasboard—8110 adopts advanced design of hardware together with integrated software analysis technology. Petrol engine or diesel engine‘s RPM is obtained through analysis of ...
Temperature: -10 °C - 50 °C
Noise level: 120 dB
Voltage: 9 V
HD9120 is an acoustic calibrator that, in accordance with the Circular Prot. RU 34143 of 02 December 2011, allows qualified technicians to perform calibrations of sound level meters for comparison with a reference sound ...
Delta OHM
Extrusion lines for the production of PROFILES The patented MULTIDRIVE technology of the Bausano MD Plus extruder range and a long-standing experience in plastic processing allow Bausano to ensure high performance and great reliability ...
Temperature: 0 °C - 50 °C
Partial discharge calibrator KAL 9511 is a successor to the popular Tettex 9216. KAL 9511 covers a wide range of applications. It is compact, easy to use and has the same long battery operation capability of Tettex ...
Application : Calibration System for Bottom Bracket Bearings Technical Details : Calibration of torque sensors in bottom bracket bearings for bikes. Range up to 100 N·m at 150 min-1. Measurement of torque, speed and ...
Temperature: -10 °C - 55 °C
Voltage: 115, 120 V
The LCc-II load cell calibration indicator uses microprocessor technology to store ten individual, ten point linearized, load cell calibration curves. This capability allows this device to be used as a calibration force measurement ...
Vishay Nobel Transducers
The load cell tester 1008 allows to test and calibrate a four load cell system in only few minutes, using a simple but practical serial cable connection. The LCT 1008 allows for download of measurement results to a PC via an USB or RS232 ...
Nobel Weighing Systems
Temperature: 18 °C - 28 °C
Epsilon’s very high resolution calibrator features 20 nanometers (0.8 microinches) resolution and has 50 mm (2 inches) of measuring range. The 3590VHR calibrator meets the accuracy and resolution requirements ...
Epsilon Technology
Temperature: 18 °C - 28 °C
Epsilon’s standard calibrator features 0.001 mm (50 microinches) resolution and has 50 mm (2 inches) of measuring range. The autozero button and digital display greatly simplify calibration of extensometers. The 3590 ...
Epsilon Technology
Temperature: 18 °C - 28 °C
Epsilon’s axial/torsional calibrator features 0.001 mm (50 microinches) resolution, and has 50 mm (2 inches) of measuring range axial and torsional rotation where 1.27 mm (0.050 inch) of linear motion equates to 1° angle ...
Epsilon Technology
Temperature: 0 °C - 50 °C
Voltage: 9 V
HI931002 is a portable simulator designed to monitor and regulate 4-20 mA from practically any process meter with or without a voltage generator. HI931002 can measure incoming current, provide power, and simulate 4-20 mA output to calibrate ...
... gases of interest. It meets all U.S. environmental protection agency requirements. Multi-gas calibrator for ambient air gas analyzers' MULTI-GAS CALIBRATOR FOR AMBIENT AIR GAS ANALYZERS' MGC101 The ...
Voltage: 230 V
... connected to the UT-3000 Ultratracer. With a special syringe a defined volume of mercury containing gas is drawn from the calibrator and injected into the calibration port of the UT-3000. After entering the volume ...
Voltage: 230 V
This is an accesory for the UT-3000 Mercury Ultratracer in monitoring systems at low to intermediate mercury concentrations The Mercury Instruments Automatic Calibration Unit consists of a specially designed mercury vessel containing ...
Temperature: 5 °C - 35 °C
Multipoint dilution and permeation system developed in collaboration with the METAS (Swiss Federal Institute of Metrology). The most complex configuration consists in a double stage dilution and permeation system. The device can be available ...
LNI SWISSGAS
... installed in an air pollution monitoring station to measure gases such as SO2, HC, BTX, CO, NOx and O3. It is a multigas calibrator with GPT, ozone and self re‐generable zero air and can also be used to monitor and ...
LNI SWISSGAS
The Multipoint Multigas Calibrator Sx 6000C1 is engineered to calibrate either manually or by remote control, up to 5 gas screens setup in the AIR contamination scanning panel like such as SO2, HC or BTX, CO, NOx and ...
LNI SWISSGAS
Voltage: 0 V - 40,000 V
The Buckleys Calibration Meter Pro’ offers a quick, accurate and cost-effective method of checking the calibration state of high-voltage DC equipment. It has been primarily designed for use with the Buckleys’ PHD Pro’, PD and PHD range ...
The Calibration Kit has been created to provide all the necessary components to enable customers to verify the accuracy of the readings on the Buckleys or Roxby BathyCorrometers so that ‘in-house’ calibration certificates can be issued. The ...
The Calibration Kit has been created to provide all the necessary components to enable customers to verify the accuracy of the readings on the Buckleys Contact and Proximity Probes so that ‘in-house’ verification certificates can be issued. Providing ...
Ateq presents CDF60 leak/flow calibrator. It is used to check the calibration of leak and flow measurement instruments. It is also used for testing calibrated leaks and jets. The calibrator is lightweight, ...
Temperature: 5 °C - 45 °C
The CDF7000 allows you to check the calibration of leak and flow measurement instruments, as well as calibrated leaks and jets. This portable, compact and user-friendly instrument lets you adjust very accurately your leak or flow rate ...
ATEQ presents CDP60 leak/flow calibrator. It has been dedicated to calibration. It is highly dependable and is traceable to international standards. The calibrator is used for testing the pressure calibration ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining