Product overviewMIC500-OZ wall-mounted ozone analyzer based on the Lambert–Beer law with dual UV light source and separated optical cuvette technology for continuous industrial monitoring.
Key functional descriptionThe instrument uses a high-definition 4.3" touch screen showing real-time ozone concentration with pressure and temperature compensation. For high-concentration ranges (g/Nm3) it supports external flow input to display ozone generator output in real time. The core employs a long-life UV light system and high-transmittance quartz to minimize zero drift. Zeroing can be performed without interrupting ozone input to allow 24/7 operation.
Modifiable parameters- Pressure unit display (kPa)
- Alarm settings (high/low thresholds)
- Carrier gas type: air or oxygen (including PSA)
- RS-485 interface parameters
- 4–20 mA output configuration
Range / sampling method / application areas0–300 g/Nm3 | Active pressure sampling, pressure & temperature compensation | Real-time monitoring of ozone generator outlet concentration
0–100 g/Nm3 | Active pressure sampling, pressure & temperature compensation | Real-time monitoring of ozone generator outlet concentration
0–50 g/Nm3 | Active pressure sampling, pressure & temperature compensation | Real-time monitoring of ozone generator outlet concentration
0–1000 ppm | Active pressure sampling or pumped sampling, pressure & temperature compensation | Real-time monitoring of ozone concentration in enclosures
0–100 ppm | Active pressure sampling or pumped sampling, pressure & temperature compensation | Real-time monitoring of room or space ozone concentration
Technical featuresDetection method: dual-beam UV photometric absorption (Lambert–Beer law) with long-life UV light source and high measurement accuracy.
Light source: imported long-life UV lamp (253.7 nm); 3-year free warranty for the light source.
Installation: indoor wall-mounted; provide power and signal connections.
Cuvette system: separated optical cuvette with no leakage; resistant to high pressure and sampling-gas impact.
Intelligent compensation: built-in temperature and pressure compensation and automatic light-source compensation.
Operation: manual or automatic zeroing selectable; automatic zeroing time adjustable.
Interface: 4.3" touch screen with gas mass flow and real-time output display.
Display units: g/Nm3, mg/NL, %wt, ppm, mg/Nm3 (optional). Units can be changed during operation.
Outputs: 4–20 mA active output, RS-485 (Modbus-RTU), two alarm relay outputs, electronic flowmeter input.
Standard accessories: anti-corrosive flowmeter, ozone tail-gas destroyer, gas input filter.
Power input / alarm & signal outputs (summary)Power input terminals: L = 220 VAC L, N = 220 VAC N, GND provided.
Alarm outputs: two relay contacts for high and low alarm (NO / COM / NC).
Signal outputs: RS-485 (Modbus-RTU) and 4–20 mA active output (4–20 mA+ / 4–20 mA-), RS485+ / RS485- terminals.
Operation & maintenance notesRecommend 5 min preheat then perform zeroing before normal use. Built-in UV light monitoring and automatic adjustment according to lamp brightness. Manual zeroing available to correct zero deviation when no ozone present.
Cautions: use indoors in ventilated, dry environments without corrosive gases (e.g., NH3, HCl, H2S). For humid or oil-containing gas, install pre-treatment (filters, dehumidifiers) at the instrument inlet. Do not disassemble; professional maintenance only. Keep the unit clean and avoid scratching the touch screen. Cut power and gas source in abnormal situations.
Specifications- Model: MIC500OZ
- Test ranges: 0–300 g/Nm3, 0–200 g/Nm3, 0–100 g/Nm3, 0–50 g/Nm3, 0–1000 ppm, 0–100 ppm
- Display resolution: 0.01 g/m (note: 1 mg/L = 1 g/m3 ≈ 467 ppm)
- Display units: g/Nm3, mg/NL, %wt, ppm
- Sampling method: active pressure sampling or pumped sampling
- Measured parameters: ozone concentration, temperature compensation, pressure compensation
- Light source life: approx. 30,000–50,000 hours
- Display: 4.3" touch screen
- Auxiliary functions: temperature & pressure compensation
- Sampling flow: 0.5 L ± 0.2 L/min
- Input pressure: < 0.1 MPa
- Concentration error: < 0.3% FS
- Linearity deviation: < 0.2% FS
- Zero drift: < ±0.3% FS
- Response time: signal 0.03 s; display 0.3 s
- Ambient temperature: -20 to 50 °C
- Sampling connection: bypass sampling Φ6 (6×4 mm quick-fit) or Φ8 (8×6 mm quick-fit)
- Communication: RS-485 (Modbus-RTU); 9600,8,N,1; data format hexadecimal
- Outputs: 4–20 mA active output; RS-485 (Modbus-RTU)
- Relay signals: high and low alarm relay outputs
- Power supply: AC 110–220 V
- Dimensions: 230 mm (H) × 330 mm (W) × 150 mm (D)
- Options: anti-corrosive flowmeter, filter, ozone tail-gas destroyer, sampling pump
- Recommended calibration interval: factory calibration every 12–18 months (return/transport costs borne by user)