Gas detector MIC300OZ
ozoneultraviolet lightUV photometry

Gas detector - MIC300OZ - Beijing Zetron Technology Co., Ltd. - ozone / ultraviolet light / UV photometry
Gas detector - MIC300OZ - Beijing Zetron Technology Co., Ltd. - ozone / ultraviolet light / UV photometry
Add to favorites
Compare this product

Characteristics

Detected entity
gas
Gas type
ozone
Technology
ultraviolet light, UV photometry
Application
for the food industry, for water treatment, for wastewater treatment, for the chemical industry, for swimming pool
Output
4-20 mA, RS-485
Other characteristics
with alarm, waterproof, with digital display, with temperature sensor

Description

Product Overview
MIC300OZ is a microprocessor-based dual-beam UV photometer (UV 254 nm) designed for continuous measurement of ozone concentration in air or oxygen. The instrument measures UV radiation in both measurement and reference channels and records temperature and pressure in the cuvette to provide compensated ozone readings. The unit features a 4.3 in touchscreen displaying real-time ozone concentration with temperature and pressure compensation. For high-concentration applications (g/Nm3) it accepts a flow input to calculate and display ozone generator output in real time. The optical system uses a long-life UV light source and high-transmittance quartz to minimize zero drift and maintain measurement stability. Continuous 24-hour operation is supported without closing the ozone inlet during zeroing.

Features
  • Measurement principle: dual-path UV absorption (Lambert-Beer law) for high accuracy.
  • Optical system: long-life ultraviolet LED with lens and high-transmittance quartz; light source warranty 2 years (free).
  • Automatic zero: patented automatic zero-point adjustment to reduce drift.
  • Compensation: built-in temperature and pressure compensation with real-time display.
  • High-range support: flow signal input for real-time ozone generator output monitoring (g/Nm3 ranges).
  • Installation: recommended for indoor installation; unit equipped with waterproof aviation connectors.
  • Sampling robustness: separate light pool technology, leak-free and resistant to high-flow sampling impacts.


Product structure composition
INLET - IN: Analyzer inlet placed in series in the ozone pipeline; if bypass sampling is used, this is the ozone inlet.
INLET - OUT: Analyzer outlet placed in series in the ozone pipeline; if bypass sampling is used, this outlet will be blocked.
OUTLET - OUT: Analyzer outlet includes a built-in ozone destroyer so exhaust has no ozone odor and can be discharged indoors.

Signal terminal output
  • (01) 4-20MA+ — current signal output (+)
  • (02) 4-20MA- — current signal output (-)
  • (03) RS485+ — communication interface (+)
  • (04) RS485- — communication interface (-)
  • (05) ALARM HIGH: NO — high alarm (normally open)
  • (06) ALARM HIGH: COM — high alarm (common)
  • (07) ALARM HIGH: NC — high alarm (normally closed)
  • (08) ALARM LOW: NO — low alarm (normally open)
  • (09) ALARM LOW: COM — low alarm (common)
  • (10) ALARM LOW: NC — low alarm (normally closed)
  • (11) FLOW SIGNAL+ — flow signal input for yield calculation (+)
  • (12) FLOW SIGNAL- — flow signal input for yield calculation (-)
  • (13) FUNCTION+ — reserved function interface for ozone generator deployment (+)
  • (14) FUNCTION- — reserved function interface for ozone generator deployment (-)


Selectable ranges and operating modes
  • 0–300 g/Nm3 — active pressure sampling with temperature & pressure compensation — real-time monitoring of ozone generator outlet.
  • 0–100 g/Nm3 — active pressure sampling with temperature & pressure compensation — real-time monitoring of ozone generator outlet.
  • 0–50 g/Nm3 — active pressure sampling with temperature & pressure compensation — real-time monitoring of ozone generator outlet.


Applications
  • Ozone generator manufacturers
  • Municipal water treatment and disinfection
  • Industrial wastewater treatment
  • Fine chemicals and synthesis
  • Food and beverage water treatment
  • Space and surface disinfection, swimming pool disinfection
  • Fragrance and specialty chemical synthesis


Technical specifications
  • Model: MIC300OZ
  • Measuring range: standard 0–200 g/Nm3 (options: 0–300, 0–100, 0–50 g/Nm3)
  • Light source life: approx. 30,000–50,000 hours
  • Sampling mode: positive (active) pressure sampling
  • Display: 4.3 in touchscreen interface
  • Displayed parameters: ozone concentration, temperature, pressure
  • Auxiliary functions: temperature compensation, pressure compensation
  • Display units: g/Nm3, mg/NL (optional)
  • Display resolution: 0.01 g/Nm3
  • Gas flow: 0.5 L ± 0.2 L/min
  • Input pressure: < 0.1 MPa
  • Concentration error: ±0.5% FS
  • Linearity error: ±0.5% FS
  • Zero point drift: < ±0.3% FS
  • Response time: ≤ 1 second
  • Operating temperature: -30 ~ 80 ℃
  • Piping interface: quick-tightening (stainless steel)
  • Bypass sampling aperture: Φ6 (6 mm × 4 mm)
  • Communication: RS-485
  • Analog output: 4-20 mA (active)
  • Power supply: 24 V DC
  • Dimensions: 120 mm (H) × 160 mm (W) × 60 mm (D)
  • Conversion note: 1 mg/L = 1 g/m3 = 467 PPM (reference)
  • Warranty: 24 months (host)