Product overviewThe UVOZ-1100 wall-mounted ozone gas concentration analyzer provides continuous online measurement of ozone in industrial environments, pipelines, containers and enclosed spaces. It combines UV dual-path absorption with separated light pool technology and an intelligent lamp management system for fast readiness, stable baseline and simplified maintenance.
Detection principle & operationDetection principle: UV dual-path absorption (Lambert-Beer photometric absorption).
Operation interface: 4.3-inch color touch screen displaying ozone concentration, temperature and pressure in real time. Supports manual and configurable automatic zeroing times.
Key product features- UV dual-path absorption with long-life UV light source for reliable photometric measurement
- Separated light pool design: leak-proof and resistant to pressure and high-flow sampling impact
- Intelligent lamp management for rapid warm-up and stable zero point
- Built-in temperature and pressure compensation; automatic light source compensation
- Continuous 24-hour operation; zeroing can be performed without interrupting sampling
- Selectable display units: ppm or mg/Nm3
- Standard outputs: active 4–20 mA, RS-485, two relay alarm outputs
- Standard accessories: ozone exhaust destructor and air intake filter
ApplicationsDesigned for monitoring ozone generator outlets and ambient or pipeline ozone concentrations. Typical sectors: ozone generator manufacturers, municipal water treatment, industrial wastewater treatment, fine chemicals, food and beverage water treatment, space disinfection, swimming pool disinfection and flavor synthesis.
Range / Sampling / Application (summary table)- 0–1000 ppm — Positive or negative pressure sampling with pressure & temperature compensation — Real-time detection of ozone concentration in enclosures/boxes
- 0–100 ppm — Positive or negative pressure sampling with pressure & temperature compensation — Real-time detection of ozone concentration in rooms or spaces
Model & parameter table (UVOZ-1100)- Model: UVOZ-1100
- Measurement range: 0–100 ppm (standard); optional 0–1000 ppm
- Light source life: approx. 20,000–30,000 hours
- Sampling method: negative pressure sampling (positive/negative sampling with pressure & temperature compensation available)
- Display interface: 4.3-inch touch screen
- Displayed parameters: ozone concentration, temperature, pressure
- Auxiliary functions: temperature compensation, pressure compensation
- Display unit: ppm, mg/Nm3 (optional)
- Display resolution: 0.01 ppm
- Sampling gas flow: 500 mL/min
- Input pressure: atmospheric (101 kPa)
- Concentration error: max 0.3% FS (intermittent zero sampling)
- Linearity error: max 0.3% FS (intermittent calibration zero sampling)
- Zero drift: < ±0.3% FS
- Response time: signal 0.03 s, display update every 5 s
- Ambient temperature: -20 to 50 °C
- Piping interface: pagoda connector (luer inlet filter)
- Bypass sampling calibre: Φ6 (6 mm × 4 mm)
- Communication: RS-485
- Output: 4–20 mA (active)
- Relay signals: high and low alarm relays
- Power supply: 24 V DC
- Dimensions: 160 × 330 × 110 mm (H × W × D)
Warranty & notesFree warranty: 12 months for main unit. Standard built-in items: ozone exhaust catalyst and air intake filter. Follow recommended maintenance and calibration intervals for reliable operation.
Technical specifications- Detection method: UV dual-path absorption
- Core components: long-life UV light source and high-transmittance quartz plates
- Zeroing: automatic and manual; zeroing without stopping ozone intake
- Measurement accuracy: concentration and linearity error up to 0.3% FS
- Display resolution: 0.01 ppm
- Sampling flow rate: 500 mL/min
- Operating temperature: -20 to 50 °C
- Power: 24 V DC
- Outputs: 4–20 mA, RS-485, two relay alarm outputs
- Piping interface: pagoda connector / luer inlet filter; bypass calibre Φ6
- Dimensions: 160 × 330 × 110 mm (H × W × D)
- Light source life expectancy: ~20,000–30,000 hours