Type 2 surge protection unit MSB10 series
type 3for electrical installationswith fault indication

Type 2 surge protection unit - MSB10 series - CITEL - type 3 / for electrical installations / with fault indication
Type 2 surge protection unit - MSB10 series - CITEL - type 3 / for electrical installations / with fault indication
Add to favorites
Compare this product

Characteristics

Type
type 2, type 3
Applications
for electrical installations
Other characteristics
with fault indication, thermoplastic, MOV, compact, gas discharge tube, wall-mount, hard-wired
Open circuit voltage

6 kV

Description

Key features
  • Compact Type 2+3 surge protector for low-voltage systems
  • Wall or plate mounting with hard-wired connection
  • Status and disconnection indicators (green LED)
  • Protection rating: IP65
  • Certified UL1449 edition 5; compliant with IEC/EN 61643-11
  • MOV + GDT hybrid technology


Overview
The MSB10-120(UL) is a compact coordination surge protector designed to provide secondary protection for sensitive equipment in industrial and commercial low-voltage installations. It is intended to be installed downstream of a primary surge device, offering reliable clamping and controlled discharge behavior based on varistor technology with gas discharge tube assistance.

Electrical Properties
  • SPD type: IEC 2+3
  • Network: 120 V single-phase
  • AC system: TT-TN
  • Nominal line voltage (Un): 120 Vac
  • Max. AC operating voltage (Uc): 150 Vac
  • Temporary Over Voltage (TOV) 5 s (UT): 180 Vac (withstand)
  • Temporary Over Voltage (TOV) 120 min (UT): 230 Vac (disconnection)
  • Operating current (Ic): None (continuous at Uc)
  • Follow current: None
  • Nominal discharge current (In) 15 x 8/20 µs: 3 kA
  • Max. discharge current (Imax) 8/20 µs per pole: 10 kA
  • Combination waveform withstand (IEC 61643-11, class III 1.2/50µs-8/20µs) Uoc: 6 kV
  • IEEE overvoltage withstand: 10 kV / 10 kA
  • Protection modes: Common and differential mode
  • Protection level Up L/N @ In (8/20µs): 1 kV
  • Protection level Up L/PE @ In (8/20µs): 1 kV
  • Admissible short-circuit current (Isccr): 10 000 A


Mechanical Properties
  • Technology: MOV + GDT
  • Connection to network: Hard-wired (wires)
  • Mounting: Wall or plate
  • Housing material: Thermoplastic UL94 V-0
  • Operating temperature: -40 to +85 °C
  • Protection rating: IP65
  • Failsafe mode: Disconnection from AC network on end-of-life
  • Disconnection indicator: Green LED OFF; Operating indicator: Green LED ON


Norms & Certifications
  • Standards: IEC 61643-11 / EN 61643-11
  • Certification: UL1449 ed.5, EAC


Deconnector
  • Thermal disconnector: Internal
  • Recommended installation residual-current device (if present): Type 'S' or delayed


Schematics
Refer to the product schematics and wiring diagram for detailed installation, terminal identification and recommended grounding practices.

Technical specifications
  • Reference / Model: MSB10-120(UL)
  • Part Number: 561601
  • SPD type: 2+3
  • Network: 120 V single-phase (TT/TN)
  • Nominal voltage Un: 120 Vac
  • Max. AC operating voltage Uc: 150 Vac
  • TOV 5 s: 180 Vac withstand
  • TOV 120 min: 230 Vac disconnection
  • In (15 x 8/20 µs): 3 kA
  • Imax (8/20 µs per pole): 10 kA
  • Combination waveform Uoc (IEC): 6 kV
  • IEEE withstand: 10 kV / 10 kA
  • Protection levels Up L/N and L/PE @ In: 1 kV
  • Isccr: 10 000 A
  • Technology: MOV + GDT
  • Mounting: Wall or plate
  • Housing: Thermoplastic UL94 V-0
  • Operating temperature: -40 to +85 °C
  • Protection rating: IP65
  • Thermal disconnector: Internal
  • Certifications: UL1449 ed.5, EAC
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.