Water analyser W510-DCD10.1
processindustrialpH

Water analyser - W510-DCD10.1 - DABECO Co.,Ltd - process / industrial / pH
Water analyser - W510-DCD10.1 - DABECO Co.,Ltd - process / industrial / pH
Water analyser - W510-DCD10.1 - DABECO Co.,Ltd - process / industrial / pH - image - 2
Add to favorites
Compare this product

Characteristics

Measured entity
water
Application domain
process, industrial
Measured value
pH
Configuration
online
Mode of use
automatic
Protection level
IP65
Other characteristics
calibration, digital

Description

Online Chlorine Dioxide Analyzer with CD10.1 Sensor for Processing Water The online chlorine dioxide analyzer is equipped with a German-made CD10.1 sensor, adopting special osmotic membrane technology. It resists chemical interference (mainly surfactants), reduces pH dependence, and is not restricted by water quality. With fast response, stable performance, low cost, minimal maintenance, it delivers reliable and accurate data. Its application fields include tap water, chlorine dioxide generator, sewage treatment, pipeline disinfection and fruit and vegetable disinfection etc. Application Fields Tap water: 0 - 2mg/L; Chlorine dioxide generator: 0 - 20mg/L; Sewage treatment: 0 - 20mg/L; Pipeline disinfection: 0 - 2.5mg/L (water temperature up to 70℃); Fruit and vegetable disinfection: 0 - 200mg/L. Technical Parameters Measurement Parameters Chlorine dioxide, pH (optional) Measuring Ranges 0.0050.500mg/L; 0.0052.000mg/L; 0.055.00mg/L;0.0510.00mg/L; 0.0520.00mg/L Lower Limit of Measurement 0.005mg/L Resolution 0.001mg/Ldepending on the measuring range Accuracy (@25℃, pH 7.2) In the measurement range of 0 - 1ppm, when calibrated at 0.5ppm, the error is ±2% of the measured value or ±0.03ppm.take the larger one In the measurement range of 1 - 2ppm, when calibrated at 1.5ppm, the error is ±2% of the measured value or ±0.03ppm.take the larger one) In the measurement range of 0 - 10ppm, when calibrated at 5.0ppm, the error is ±2% of the measured value or ±0.3ppm.take the larger one) In the measurement range of 10 - 20ppm, when calibrated at 15.0ppm, the error is ±5% of the measured value or ±0.5ppm.take the larger one) Response time T90≈2 - 8 minutes Repeatability ≤3% Drift Approximately - 1% per month (after calibration at 25℃ and pH = 7.2) PH range 1.0 - 12.0 (depending on the electrode)

Other DABECO Co.,Ltd products

Online water quality analyzers

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.