Water analyzer W761-DP9.3
acidsignalbeverage

Water analyzer - W761-DP9.3 - DABECO Co.,Ltd - acid / signal / beverage
Water analyzer - W761-DP9.3 - DABECO Co.,Ltd - acid / signal / beverage
Add to favorites
Compare this product

Characteristics

Measured entity
signal, water, acid
Application domain
food, beverage, industrial
Measured value
concentration, temperature, pressure, pH, voltage, flow, conductivity, resistance
Mode of use
automatic
Protection level
IP65, IP68
Other characteristics
digital, calibration, control, high-temperature

Description

Product Information The analyzer consists of an LCD display instrument and a Germany-made P9.3 PAA sensor adopting a membrane-covered amperometric 2-electrode system to accurately measure PAA concentration in aqueous solutions. It delivers temperature-compensated analog signals and Modbus RTU digital signals, supports calibration via downstream devices and direct connection to dedicated transmitters with one-key calibration. Features include high-temperature tolerance (up to 60℃ water temperature), chemical/surfactant-resistant elastomer membrane, acid conductivity tolerance, <2%~3% accuracy (for 2000 mg/L range), T90 response time 45s~3.5min, flexible connectivity and IP65/IP68 protection, is EMC/RoHS compliant, requires minimal maintenance, and is ideal for water treatment in electroplating, pharmaceutical, food and beverage, dairy, and chemical industries (e.g., bottle washing machines, CIP plants). Application Fields Electroplating plants, pharmaceutical industry, food and beverage industry, dairy factories, chemical industry. Product Features - Dual-electrode measurement system - Suitable for high water temperatures (up to 60℃) - Equipped with chemical and surfactant-resistant membrane structure - Simple calibration - Integrated temperature compensation function - Tolerates acidic conductivity Technical Data Sheet Parameter: Specifications Measured Parameter: Peracetic Acid (PAA) Applicable Scope: All types of water treatment (e.g., bottle washing machines, CIP equipment, rinsers); Tolerates control acids and surfactants Measuring Principle: Membrane-covered amperometric dual-electrode measurement system Membrane Type: Hydrophilic membrane Measuring Cable Connection: 2-pole terminal connection (2×1mm²); 5-pole M12 aviation connector Supply Voltage (UB): DC 12~30V (electrically isolated required); DC 9~30V (electrically isolated from the sensor) Electromagnetic Compatibility (EMC): Emission: Class B; Immunity: Meets industrial requirements Output Signal: 4~20 mA/0~±2V; Modbus RTU Load/Current Consumption: ≤(UB-7.5V)÷0.02 A; Approx. 20-56 mA Run-in Time: Measuring range 200 mg/L: Approx. 3 hours for first use; Measuring range 2000 mg/L: Approx. 1 hour for first use; Measuring range 20000 mg/L: Approx. 30 minutes for first use Flow Rate: 15~30 L/H (in flow cell) Measuring Range: 0.5~200 mg/L (ppm); 5~2000 mg/L (ppm); 0.005~2% Resolution: 0.1 mg/L (for 200 mg/L range); 1 mg/L (for 2000 mg/L range); 0.001% (for 2% range) Accuracy (for 2000 mg/L range): <2% at 400 mg/L; <3% at 1600 mg/L Response Time (T90): Approx. 3.5 minutes at 10 °C; Approx. 45 seconds at 45 °C Operating Temperature: Water temperature: 0~60℃; Ambient temperature: 0~55℃ Temperature Compensation: Automatic via integrated temperature sensor; Sudden temperature changes must be avoided Zero Point Calibration: Not required Slope Calibration: Determined by chemical analysis method pH Operating Range: pH 1~8 Influence of Acidic Conductivity: 1% sulfuric acid, 1% nitric acid, or 1% phosphoric acid in water has no impact on measurement results Interferences: O3: Significant increase in measured value; ClO2: Increase in measured value; H2O2: No influence Pressure Resistance: Pabs max. 2 bar; Prel max. 1 bar Materials: Elastomer membrane, PEEK, stainless steel 1.4571 Dimensions: Diameter 25 mm, length 190 mm or 220 mm (housing with membrane cap, length depends on connection type); Diameter 25 mm, length 205 mm (housing with membrane cap) Weight: Approx. 125 g Key Specifications / Features - LCD display instrument with Germany-made P9.3 PAA sensor - Membrane-covered amperometric 2-electrode system - Temperature-compensated analog and Modbus RTU digital signals - One-key calibration and flexible connectivity - High-temperature tolerance (up to 60℃ water) - Chemical/surfactant-resistant elastomer membrane - Acid conductivity tolerance - <2%~3% accuracy (for 2000 mg/L range) - T90 response time 45s~3.5min - IP65/IP68 protection, EMC/RoHS compliant - Minimal maintenance - Ideal for water treatment in electroplating, pharmaceutical, food and beverage, dairy, and chemical industries

Catalogs

No catalogs are available for this product.

See all of DABECO Co.,Ltd‘s catalogs

Other DABECO Co.,Ltd products

Online water quality analyzers

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.