Product Overview
Equipped with a reliable, economical amperometric sensor for continuous measurement of free chlorine or chlorine dioxide in drinking water and process applications. With a durable PVC-U housing, it suits standard environments (≤50°C) by balancing performance and value.
Its core potentiostatic three-electrode system ensures high accuracy and long-term signal stability, supporting effective disinfection control. Easy to integrate, it offers multiple electronic options: analog voltage, digital processing (analog/digital Modbus RTU), and 4-20 mA current loop.
It features automatic temperature compensation and enables indefinite dry storage (no electrolyte), simplifying inventory management. As a cost-effective, reliable choice, the W761-DAS2 excels in standard water treatment—from municipal drinking water to industrial process water—where extreme conditions are absent.
Working Principle
W761-DAS2 contains a display instrument and a versatile and cost-effective amperometric sensor for continuous monitoring of free chlorine or chlorine dioxide. With its PVC-U housing, it is designed for reliable performance in standard drinking water and process water applications up to 50°C, providing a robust and economical solution for disinfection control.
Application Fields
- Disinfection control in municipal drinking water treatment plants.
- Monitoring of chlorine levels in commercial and residential building water systems.
- Process water treatment in various industrial settings (where temperature is ≤ 50°C).
- Cooling water systems operating within standard temperature ranges.
Functional Features
- Cost-Effective & Robust: PVC-U housing provides durability for standard applications.
- Precise Measurement: Potentiostatic 3-electrode amperometric system ensures accuracy.
- Output Flexibility: Available in analog (voltage/4-20 mA) and digital Modbus RTU versions.
- Optimized Maintenance: Optional RV1 cleaning accessory extends maintenance intervals.
- Logistical Advantage: Can be stored dry (without electrolyte) indefinitely.
Technical Parameters
Parameter | Specification
--- | ---
Measurands | Free Chlorine (AS2-CL), Chlorine Dioxide (AS2-CD)
Application Medium | Drinking Water, Process Water (up to 50°C)
Housing Material | PVC-U
Measuring Ranges (example) | CL (H): 0.005...2.000 ppm (without RV1)
Output Signals | Analog: 0...±2 V, 4...20 mA; Digital: Modbus RTU
Max. Working Pressure | 8 bar (with retaining ring in flow chamber)
Operating Temperature | Water: 0...+50°C
pH Range | CL: pH 5 - pH 9
Response Time (T90) | ≈ 30 seconds
FAQ – Frequently Asked Questions
- Manufacturing: Designed and manufactured in China, following international quality standards and certified processes.
- OEM/ODM: Customized solutions and private labeling available for global clients.
- Certifications: Products meet CE, RoHS, and other international certifications.
- Shipping: Fast and reliable delivery via major international couriers.
- Samples: Product samples available before bulk orders.
- Lead Time: Standard products ship within 5–7 days after order confirmation; customized products may take longer.
- Support: 24/7 technical support, product guidance, and warranty service.
- International Support: Remote technical assistance, English manuals, and prompt solutions for global clients.
- Ordering: Orders can be placed via website inquiry or email, with professional guidance provided.
- Why Choose Us: Over 30 years of manufacturing experience, advanced technology, strict quality control, and global customer service.
Characteristics / Technical Specifications
- Model: W761-DAS2
- Measurement: Free Chlorine or Chlorine Dioxide
- Sensor Type: Amperometric, potentiostatic 3-electrode system
- Housing: PVC-U
- Temperature Range: 0...+50°C
- Pressure: Up to 8 bar
- Output: Analog (0...±2 V, 4...20 mA), Digital (Modbus RTU)
- pH Range: 5 - 9 (for chlorine)
- Response Time: ≈ 30 seconds
- Maintenance: Optional RV1 cleaning accessory
- Storage: Can be stored dry, no electrolyte required