Product overviewThe ultrasonic generator converts mains frequency (50/60 Hz) into higher operating frequencies. Designed for industrial cleaning applications, the GUV series integrates automatic output frequency modulation to optimize conversion efficiency according to the load in the washing tank. All generators include 0–100% ultrasonic output power regulation to adapt cleaning intensity.
Standard functions- Customized programs: program and store up to 3 distinct washing cycles (time and power).
- Degasification program: accelerates liquid degassing to improve cleaning consistency.
- Password protection: restrict access to additional programs to authorized personnel.
- Warning counter: logs occurrences of non-optimal operating states.
- Remote control: enable/disable control via a 0–5 V remote input.
- Alarm notification: machine enters alarm mode if load causes >10% error in supplied power.
Power supply optionsGenerators available for 220 V or 380 V supply, in single-phase or three-phase configurations.
Models and power (Watts)MODEL | POWER (Watts)
GUV 1000 | 1000/2000
GUV 2000 | 2000/3000
GUV 3000 | 3000/6000
GUV 4000 | 4000/8000
GUV 5000 | 5000/10000
Technical specifications- Function: converts mains frequency (50/60 Hz) to higher operating frequencies for ultrasonic transducers.
- Automatic output frequency modulation to optimize conversion efficiency based on load.
- Ultrasonic output power regulation: 0–100% for precise control of cleaning intensity.
- Programmable: up to 3 customizable washing programs (time and power).
- Degasification program to accelerate degassing of the cleaning liquid.
- Password protection to limit program access to authorized users.
- Warning counter tracking non-optimal operating conditions.
- Remote control input: 0–5 V signal to enable/disable machine control.
- Alarm mode triggered when load induces >10% power error.
- Power supply: selectable 220 V or 380 V; single-phase or three-phase versions available.
- Available models: GUV 1000, GUV 2000, GUV 3000, GUV 4000, GUV 5000 with respective power ranges.