- Robotics - Automation - Industrial IT >
- Automation >
- Analog input indicator
Analog input indicators
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... panel-mounted digital
indicator with measurement
inputs for RTD sensors, thermocouples or standard signals and a limit-value monitoring function suited for industrial process and machine control.
Highlights
- Flexible
... displays temperatures in °C or °F and standard signals in "plain text". The basic device is already equipped with 1 analog input, 2 binary inputs, 2 relay outputs, 2 logic outputs, and a voltage supply ...
... li>
... KHz and the resolution of up to 24bit ensure high levels of accuracy. Various calibration modes can be selected for the analog input (sample weight, percentage value on scale base, mV/V value). A dedicated programming ...
... display features a digital output and a configurable analog input. The input can be set either for voltage signals (0-10 V and others) or for current signals (4-20 mA and others). Before displaying, the ...
... a digital output and a configurable analog input. The device can process linear voltage signals, signals from various RTDs (Pt100, Pt1000, and others) or thermocouples (K, J, and others). Before displaying, the input ...
... Universal display 4-20 mA in a wall mount enclosure The ITP11-W is a universally-applicable display unit for monitoring of industrial processes. Scaling and square root functions are available. The ITP11-W is designed to be connected to any sensors ...
... ® Process Indicator with 2 Analog Inputs (16 bit), 3 Control Inputs • Extensive functions such as limit monitoring and analog output optionally available • ...
motrona
... - Analog value1 (scaled / linearized) and unit - Analog value2 (scaled / linearized) and unit - Analog value1 (scaled / linearized) with totalisation and unit - Analog value2 (scaled ...
motrona
... ideal for use in the food industry. Maximum flexibility is reached by arbitrarily combinable, modular configuration with analogue output, switching outputs, relay, serial interface (Modbus) and 115 / 230 VAC. Finally the extended ...
motrona
... current measurement or totalizer values Analog output for current measured value, min. value, max. value or totalizer value Sensor power supply 15 V DC / 25 mA, also for Wire transmitters Inputs ...
... Description: - Universal analog input indicator - totalizer Display: - LED 4, 6, 8, 4+7 digit Analog universal input: - mA, V, potentiometer, Pt100, TC (J, K, R, ...
SENECA | AUTOMATION INTERFACES
... I/V analog input, high accuracy class Accuracy: - 0,05% A/D converter: - 16 bit Protection degree: - IP65 Thermal drift: - 0,005%/°K Max power consumption: - < 0,9 W Loop power supply: - yes Power supply: ...
SENECA | AUTOMATION INTERFACES
... acquisition of an analogue measurement and display in engineering units. Description: - 4 digit display with I/V analog input, IP66 case High accuracy: - Max error 0,05% Max resolution: - 16 ...
SENECA | AUTOMATION INTERFACES
... SPECIFICATIONS: Analog unit: 0 … 10 VDC, 0/4 … 20 mA (switchable via jumper) Digital input: Logic 0 = 0 … 6V / logic 1 = 18-24V (maximum 1000 Hz) Ambient temperature: -10 to + 50 ° C Humidity: 5% to 90% (non-condensing) Inputs: ...
... like P, U, I, and KWh; • A variety of I/O optional including Analog Output, Analog Input, Relay Output, or Digital Output • Four keys are used to interface with the meter • Electrostatic discharge immunity: ...
... The SUR-W410 meter is equipped with one universal input, type: 0/4-20 mA, 0-10V, 0-150 mV, Pt 100/500/1000 or TC (K, S, J, T, N, R, B, E). During the measurement process only one kind of input is available. Due to wide ...
SIMEX Sp. z o.o.
... The SUR-457 meter is equipped with one universal input, type: 0/4-20 mA, 0-10V, 0-150 mV, Pt 100/500/1000 or TC (K, S, J, T, N, R, B, E). During the measurement process only one kind of input is available. As a main ...
SIMEX Sp. z o.o.
... universal input, type: 0/4-20 mA, 0-10V, 0-150 mV, Pt 100/500/1000 or TC (K, S, J, T, N, R, B, E). During the measurement process only one kind of input is available. Temperature of cold ends is compensated automatically. ...
SIMEX Sp. z o.o.
... is a versatile indicator that suits many applications. Various options are available, including Intrinsic Safety for hazardous area applications. The input circuit is separated from the backlight circuit. The F490 ...
Fluidwell bv
... The F040 is a straight forward temperature indicator with large 26mm (1") high digits. The measuring unit to be displayed below the temperature is simply selected through an alphanumeric configuration menu. No adhesive labels have to ...
Fluidwell bv
... The F090-A-PL is an economical loop powered, multi-purpose indicator with large 26mm (1”) high digits. The measuring unit to be displayed is simply selected through an alphanumeric configuration menu. No adhesive labels have to be put ...
Fluidwell bv
... ANALOGUE INPUT PANEL METERS WITH DUAL LINE DISPLAY Panel meters with two display lines for Wheatstone bridge sensors or electrical analogue measurements o Dual line display 6 digits ...
... information
Analog display module for up to 4 signals (0-10 V) with an LED ring (10 LEDs) providing a qualitative indication of the
analog level.
Application
- Visualisation of up to four
... certified 5.7" color TFT screen Constant Surface Speed (CSS) Special inputs: Emergency input, analog input for the potentiometer, external push buttons (M3, M4, Stop, etc.) Analog ...
... Process indicator for analogue signals. Displaying a process, temperature, load cell or potentiometer signal in engineering units. Mounting: 48x96mn panel Input: Process, RTD100, Thermocouple Display: ...
... CS3S-PR 4 Digital Process Meter (1/32 DIN) ● Measuring: 0~20mA/0~10V ● Accuracy: ±0.1% ● Display range: -1999~9999 ● Dimension: 1/32 DIN (48x24mm) ● High stability and reliability ...
ADTEK Electronics Co., Ltd
... design of its user interface and hardware equipment. Analog and digital inputs and outputs, counting inputs, as well as interfaces can be flexibly added to display the required process variables. The ...
... The indicator STR551 stands out in its market segment for the bright OLED display and the innovative multilingual interface as well for RFID/NFC connectivity. The analogue input can be configured by parameter ...
Pixsys
... Readings: 4 digits (9999) Thermal stability: 50 ppm/°C Accuracy input DC: < 0,5% Accuracy input AC: 2% Inputs: TC: J, K,S; RTD PT100; 0÷20mA; 4÷20mA; 0÷10V, potentiometer Analogue ...
... The RIX100 digital indicator is designed for measuring analog process signals from 4-20 mA transmitters; 0-10V; 0-5V; 1-5V; ± 10V, or any type of signal within the following ranges: ± 4 0mA, ± 4 Vdc, and ± 40 Vdc. The ...
... An internal, high gain, fully-differential amplifier and a 16-bit analog-to-digital converter combine to accurately digitize the input signal. The analog input is digitally filtered, ...
... Long distance indicator visibility is made easy with the ceiling mounted TRI-2 panorama rudder angle indicator. Extended indicator visibility With 3 windows giving a 250° viewing angle of its large ...
... display time – High sensitivity – Analog input: 0-10 V – Digital input: RS485 | RS232 | Can bus – Adjustable scale 0 – 999999 – Decimal point 1,2,3,4,5 – Simple programming menu – ...
... Series is a product line of panel meters including bargraph and/or digital displays. A variety of input types are available, including 2-wire analog input (transmitter power supply included ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group