Overview The BBFM-V105K is an ultrasonic transducer intended for use in 2D and 3D anemometers, meteorological monitoring, ventilation airflow measurement and industrial duct monitoring. It has a center frequency of 105 kHz ±5% and a recommended working range of 0.15 to 3 m. The unit features an LY12 housing, IP68 protection and a 2 m cable; typical weight is 50 g ±5%.
Beam geometry The half-power (-3 dB) beam angle is 9.1° ±10%. Sensor layout and the acoustic path between transmit and receive elements should account for this beam geometry to ensure measurement accuracy.
Technical specifications - Model: BBFM-V105K
- Center frequency: 105 kHz ±5%
- Recommended range: 0.15 to 3 m
- Minimum impedance: 540 Ω ±20%
- Capacitance: 1200 pF ±20% at 1 kHz
- Operating voltage: Peak voltage <800 Vpp
- Operating temperature: -40 to +80°C
- Pressure rating: ≤3 kgf / 0.3 MPa
- Half-power beam angle: 9.1° ±10% at -3 dB
- Housing material: LY12
- Mounting: Refer to dimensional drawing
- Protection rating: IP68
- Weight: 50 g ±5% with 2 m cable
Specified monitoring applications - 2D and 3D ultrasonic anemometers
- Meteorological monitoring
- Ventilation airflow measurement
- Industrial duct monitoring
System integration Transmit and receive electronics must be matched to the minimum impedance (540 Ω ±20%) and capacitance (1200 pF ±20% at 1 kHz). Peak voltage must remain below 800 Vpp. Verify mechanical space and alignment using the dimensional drawing. Installations must operate within -40 to +80°C and below 3 kgf (0.3 MPa) while maintaining IP68 protection.