Immersible ultrasonic transducer BBFM-Q64K
measurement

Immersible ultrasonic transducer - BBFM-Q64K - Deep Minds Ultrasonic - measurement
Immersible ultrasonic transducer - BBFM-Q64K - Deep Minds Ultrasonic - measurement
Add to favorites
Compare this product

Characteristics

Use
immersible
Applications
measurement
Frequency

Max.: 67 kHz

Min.: 61 kHz

Distance range

Max.: 5 m
(16'04" )

Min.: 0.3 m
(0'11" )

Description

Product overview
The BBFM-Q64K is a 64 kHz ultrasonic transducer for gas flow measurement, intended for industrial gas flow meters and transit‑time gas measurement modules. Reference range: 0.3 to 5 m. The acoustic field features wide-angle transmission.

Technical specifications
Model — BBFM-Q64K
Center frequency — 64 kHz ±5%
Recommended range — 0.3 to 5 m
Operating voltage — Peak voltage <1,500 Vpp
Operating temperature — -40 to +80°C
Pressure rating — ≤3 kgf or 0.3 MPa
Acoustic field — Wide-angle transmission
Mounting thread — M20 × 1.5
Protection rating — IP68
Weight — 80 g ±5%

Mechanical and environmental specifications
The mechanical interface uses an M20 × 1.5 thread. Operation is specified from -40 to +80°C and up to 3 kgf (0.3 MPa). Protection rating IP68. Stated weight: 80 g ±5%.

Electrical specification
Applied peak voltage must remain below 1,500 Vpp; ensure compatible drive/receive circuitry for 64 kHz operation.

Technical features
  • Model: BBFM-Q64K
  • Center frequency: 64 kHz ±5%
  • Recommended range: 0.3 to 5 m
  • Operating voltage: Peak voltage <1,500 Vpp
  • Operating temperature: -40 to +80°C
  • Pressure rating: ≤3 kgf or 0.3 MPa
  • Acoustic field: Wide-angle transmission
  • Mounting thread: M20 × 1.5
  • Protection rating: IP68
  • Weight: 80 g ±5%

Catalogs

No catalogs are available for this product.

See all of Deep Minds Ultrasonic‘s catalogs

Other Deep Minds Ultrasonic products

Level & Distance Measurement

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.