OverviewThe BBFM-Q25K is specified for industrial liquid flow meters, pipe velocity measurement, water-treatment flow monitoring and embedded flow measurement modules. It operates at a center frequency of 25 kHz ±5% and has a stated reference range of 500 m. Its acoustic field is horizontally omnidirectional. This directional characteristic and the required acoustic path should be considered together when arranging the transducer in a measurement system.
Technical specificationsModel: BBFM-Q25K
Center frequency: 25 kHz ±5%
Recommended range: 500 m
Minimum impedance: 150 Ω ±20%
Capacitance: 16000 pF ±20% at 1 kHz
Operating voltage: Peak voltage <500 Vpp
Operating temperature: -10 to +40°C
Pressure rating: ≤3 kgf or 0.3 MPa
Acoustic field: Horizontally omnidirectional
Mounting: Refer to product dimensional drawing
Protection rating: IP68
Weight: 390 g ±5% with 2 m cable
Specified applications- Industrial liquid flow meters
- Pipe velocity measurement
- Water-treatment flow monitoring
- Embedded flow measurement modules
Electrical and mechanical integrationThe transmit and receive electronics should be matched to the stated minimum impedance of 150 Ω ±20% and capacitance of 16000 pF ±20% at 1 kHz. Peak voltage must remain below 500 Vpp. Confirm the dimensional drawing against the available installation space. The operating conditions must remain within -10 to +40°C and no more than 3 kgf or 0.3 MPa, while preserving the specified IP68 protection.
Technical characteristics / specifications- Model: BBFM-Q25K
- Center frequency: 25 kHz ±5%
- Recommended range: 500 m
- Minimum impedance: 150 Ω ±20%
- Capacitance: 16000 pF ±20% at 1 kHz
- Operating voltage: Peak voltage <500 Vpp
- Operating temperature: -10 to +40°C
- Pressure rating: ≤3 kgf or 0.3 MPa
- Acoustic field: Horizontally omnidirectional
- Mounting: Refer to product dimensional drawing
- Protection rating: IP68
- Weight: 390 g ±5% with 2 m cable