Energy meter power meter MAP4-34RJ-TCP
multimeterwith power quality and harmonic analyzerfrequency meter

Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter - image - 2
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter - image - 3
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter - image - 4
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter - image - 5
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter - image - 6
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter - image - 7
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter - image - 8
Energy meter power meter - MAP4-34RJ-TCP - Lettel - multimeter / with power quality and harmonic analyzer / frequency meter - image - 9
Add to favorites
Compare this product

Characteristics

Associated function
energy meter, multimeter, with power quality and harmonic analyzer, frequency meter
Measured power
reactive power, active power, apparent power
Other characteristics
three-phase, with Rogowski inputs, multi-function, digital, single-phase, multi-circuit, DIN rail

Description

The MAP4-34RJ-TCP measurement units allow for complete and precise measurement of 4 three-phase circuits or 12 single-phase circuits. - Measurements: The unit can measure up to 12 single-phase circuits or 4 three-phase or tetra circuits. ➞ Current measurement: via Enerclip current transformers with RJ12 connectors. ➞ Voltage measurement: direct or via voltage transformers. - Accuracy: Active energy measurement class 0.5S. - Electrical: Auxiliary power supply 80 … 270 VAC. - Physical: 70 mm wide housing (4 modules), DIN rail mountable. Backlit LCD display with 3 display lines. Connection via RJ12 ports or removable screw terminals. - Communication: Pulse emitter on active energy. Modbus TCP/IP via RJ45 Ethernet port. Modbus RTU via RS485 port. - Inputs and outputs: The MAP4-34RJ-IO-TCP model is equipped with 4 digital inputs and 2 programmable relay outputs. - Multi-measurement: Measurement of main electrical quantities for detailed circuit analysis: active and reactive energies ┃ imported and exported ┃ voltage, current ┃ active, reactive, and apparent powers ┃ power factor ┃ frequency ┃ demands, ┃ extreme values ┃ imbalances ┃ harmonics up to the 31st order ┃ and more… - Circuit control and alarms: The 2 relays of the MAP4-34RJ-IO-TCP model are programmable for minimum or maximum thresholds of current, voltage, power, phase imbalance, etc., allowing: ➞ to protect electrical circuits ➞ to perform alarm functions in case of failure or inappropriate signal ➞ to perform automatic load shedding in case of overload. - Status reporting of electrical circuits: The 4 digital inputs of the MAP4-34RJ-IO-TCP model allow monitoring the status of auxiliary circuits or devices and alerting in case of failure or circuit interruption. - Data recording: Energy and power indexes are recorded at a programmable frequency in steps of 1 minute. The unit's recording capacity is 16,000 data lines. Recorded data can be viewed via software and exported in .csv format. - Compactness: Allows analysis of 4 three-phase or 12 single-phase circuits on a single device with a width of 4 modules. - Ease of installation: Connecting CTs via RJ12 cable reduces wiring time and eliminates risk of error. Opening current sensors allow installation without disconnecting the measured circuit. - One Modbus address per device: A single Modbus address for measurements of 4 three-phase or 12 single-phase circuits allows multiplying the number of measured circuits per RS485 loop. - Supervision: Measurement visualization on scrolling display or via comprehensive software provided free of charge. - Applications: The compact housing and easy integration make it the ideal measuring instrument for adding measurement points for branch circuits in existing electrical panels. The MAP4-34RJ measurement unit is mainly deployed for compliance with tertiary or BACS decrees. - Compliance: CE, RoHS, REACh. - Compatible current transformers: - Closed CTs: MSC-TCF - Open CTs: MSC-TCO - Rogowski coils: MSC-TCR - Technical features / specifications: - Measures up to 12 single-phase or 4 three-phase circuits - Current measurement via Enerclip CTs with RJ12 connectors - Voltage measurement direct or via VT - Active energy measurement class 0.5S - Auxiliary power supply: 80–270 VAC - 70 mm wide housing (4 modules), DIN rail mount - Backlit LCD display, 3 lines - RJ12 or removable screw terminal connections - Pulse output on active energy - Modbus TCP/IP (RJ45), Modbus RTU (RS485) - MAP4-34RJ-IO-TCP: 4 digital inputs, 2 programmable relay outputs - Data logging: up to 16,000 lines, exportable in .csv - Compliance: CE, RoHS, REACh
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.