The MSC-N2 module is a high-performance measurement center in a 1-module housing:
- Measurements:
The measurement center allows measuring 1 three-phase circuit or 3 single-phase circuits.
➞ Current measurement: via Enerclip current transformers with RJ12 connection.
➞ Voltage measurement: direct or via voltage transformers.
- Precision:
Active energy measurement class 0.5S.
- Electrical:
Self-powered on the measured circuit.
- Physical:
18mm width housing (1 module), clip-on DIN rail.
Connection via RJ12 ports or detachable screw terminals.
- Communication:
Programmable output as relay output or pulse emitter on active energy.
Modbus RTU on RS485 port (2 terminals A and 2 terminals B).
- Inputs and outputs:
The measurement center is equipped with one relay output and 2 programmable digital inputs.
- Multi-measurement:
Measurement of main electrical quantities for detailed circuit analysis:
active and reactive energies in multi-tariffs with MSC-C1 module ┃ imported and exported ┃ voltage, current ┃ active powers ┃ reactive and apparent powers ┃ power factor ┃ frequency ┃ demands, ┃ extreme values ┃ imbalances ┃ harmonics up to the 63rd order | and many more …
- Circuit control and alarms:
The MSC-N1 counter relay is programmable on reaching minimum or maximum thresholds of current, voltage, power, phase imbalance, … allowing:
➞ to protect electrical circuits
➞ to perform alarm functions in case of failure or inappropriate signal
➞ to perform automatic load shedding in case of overload.
- Circuit status feedback:
The 2 digital inputs allow knowing the status of auxiliary circuits or electrical devices and alerting in case of failure or circuit break.
- Pulse counters:
The 2 digital inputs can be set as pulse counters, to report in Modbus the consumption of gas or water meters equipped with pulse emitters.
- Compactness:
1 module width housing.
- Ease of installation:
Connecting the CTs via RJ12 cable reduces wiring time and avoids any risk of error.
Opening current sensors allow installation without disconnecting the measured circuit.
- Supervision:
Data reading and programming on the optional MSC-DE display or using the free software provided.
- Applications:
The compactness of the housing and ease of integration make it the ideal measuring instrument for adding measurement points of sub-circuits in existing electrical cabinets.
The Enerclip multi-circuit measurement solution is mainly deployed for compliance with tertiary or Bacs decrees.
- Conformities:
CE, RoHS, REACh.
- Enerclip Solution:
Current transformers type:
- Closed CTs: MSC-TCF
- Open CTs: MSC-TCO
- Rogowski loops: MSC-TCR
Flush-mounted display MSC-DE associated with the communication module MSC-C1.
- Technical notebooks:
- Electrical measurement units
- Understanding harmonic disturbances
- Negative energy problem: diagnosis and technical solutions
- Articles:
- Enerclip multi-departure solutions
- Characteristics / Technical specifications:
- Measure 1 three-phase circuit or 3 single-phase circuits
- Current measurement via Enerclip CT RJ12
- Direct voltage measurement or via transformers
- Precision class 0.5S
- Self-powered on measured circuit
- 18mm housing (1 module), DIN rail
- RJ12 connection or detachable screw terminals
- Programmable relay output or pulse emitter
- Modbus RTU RS485 (2 terminals A, 2 terminals B)
- 1 relay output, 2 programmable digital inputs
- Reading/programming via optional display or software
- CE, RoHS, REACh compliance