Phosphine detector FumiSense Pro - PH3 Hi
gaselectrochemicalfor indoor use

Phosphine detector - FumiSense Pro - PH3 Hi - Uniphos Envirotronic Pvt. Ltd. - gas / electrochemical / for indoor use
Phosphine detector - FumiSense Pro - PH3 Hi - Uniphos Envirotronic Pvt. Ltd. - gas / electrochemical / for indoor use
Add to favorites
Compare this product

Characteristics

Detected entity
gas
Gas type
phosphine
Technology
electrochemical
Application
for indoor use, for the food industry
Output
USB, ppm level
Other characteristics
hand-held, with alarm, with digital display, with data logging, with built-in pump

Description

Product Overview
FumiSense Pro PH3-Hi is a handheld phosphine (PH3) gas monitor designed to verify fumigation concentrations inside stacks, silos and ships. It features an inbuilt air sampling pump capable of drawing a sample from up to 30 m and an electrochemical sensor measuring up to 2000 ppm (optionally 5000 ppm). The backlit 20×4 OLED display provides clear readings in low light. The device supports user-configurable datalogging with date, time, warehouse/silo location and USB data transfer via supplied GUI.

Key Features
  • Measurement ranges: 0–2000 ppm (standard) and optional 0–5000 ppm
  • Resolution: 1 ppm (low range) and 10 ppm (high range)
  • 20×4 backlit OLED display and inbuilt sampling pump (sample draw up to 30 m)
  • Continuous and batch sampling modes; pump 400–800 ml/min
  • User-settable alarm set point (low-range detectors)
  • Onboard data logging with gas concentration, warehouse/silo number, date & time
  • USB interface and PC GUI for data download, sorting and report generation
  • Soft power start and function keys: UP, DOWN, SET & ENTER


Technical Specifications
  • Gas detected: Phosphine (PH3)
  • Sensor type: Electrochemical
  • Accuracy: approx. ±2% FS (dependent on calibration)
  • Signal drift: <2% per month at constant conditions
  • Power: 7.4 V Li‑ion rechargeable battery; runtime ~6–8 hours; power consumption 3.5 V DC, 60 mA
  • Inbuilt pump flow rate: 400–800 ml/min
  • Data transfer: USB communication; GUI for data handling
  • Operating temperature: -20 °C to 50 °C
  • Display: 20×4 alphanumeric OLED, backlit
  • Enclosure: High impact ABS
  • Dimensions: H 205 mm × D 38 mm × W 108/65 mm
  • Weight: 500 g
  • Accessories supplied: Dust filter, battery charger, data downloading cable, outlet coupler


Applications & Notes
  • Designed for monitoring phosphine fumigation in grain storage, silos, warehouses and ships
  • Records concentration, location and time for traceability and compliance
  • Calibration and measurement accuracy depend on calibration gas and procedure
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.