PT3100 is suitable for the media of fluid and gas. Several measure ranges are available for a variety of cutomotive, industrial and commercial applications.
Technical Data
Accuracy: ±0.5% of full scale
(±1.5% of full scale for -1~0 bar to 0~2.5 bar only)
Range: Please refer to the Measure Range Table
Power Supply: 11 to 30 volts DC
Output Signal: 4~20mA, 2-wires
EMC Compatibility: 80MHz - 1GHz
Conduit Connection: M12 & Mini DIN43650 Connectors, plastic
Material of Wetted Parts: SS316 or SS304L available
Process Connection: Thread 1/4"NPT, 1/4"PT and G1/4" Male; Clamp 1" (IS02852) / 25(DIN32676) and 1-1/2" (IS02852)/ 32 (DIN32676) available