The PD40/41 differential pressure transmitters are characterized by a robust design and a significantly high overload capability. The stainless steel membrane and process connection are laser-welded, resulting in high media resistance and long-term stability. Each measuring range is temperature compensated, which in combination with the piezoresistive measuring principle results in a very accurate measurement even at lowest pressures. Various electrical connection options allow easy integration and are protected against dust and water with IP 67.
Features
Measuring sensor with stainless steel membranes made of 1.4404
Negative pressure measuring range: up to -20 bar
Accuracy ≤ 0,2%
One-sided overload capability up to 250 bar
Rugged industrial design
Applications:
Hygiene applications
Viscous and pasty media
Aggressive media
Pressure superimposed level measurement
Technical data:
- Negative pressure measuring range: up to -20 bar
Analog output - 4…20 mA, 2-wires
- 0…10 V, 3-wires
Power supply - 20 mA output: 9…30 V DC
- 10 V output: 15…30 V DC
Accuracy - ≤ ± 0,2 % FS @ 25 °C
Long term stability - ≤ ± 0,1 % FS / Year
Static pressure influence - ≤ ± 0,1 % FS/ 10 bar
Hysteresis - ≤ ± 0,05 % FS
Response time - 200 ms - others on request
Switch-on time - < 1 s
Temperature coefficient - Zero: ≤ ± 0,02 % FS / Kelvin
- Span: ≤ ± 0,02 % FS / Kelvin
Medium temperature - -25…120 °C
Surrounding temperature - -25…85 °C
Storage temperature - -40…85 °C
Short-circuit resistance - Permanent
Reverse polarity protection - Protection against reverse polarity, but no function