The P131 pressure transmitter features large process connections and a front-flush measuring sensor. Clogging of the membrane is prevented most effectively and can be easily cleaned if necessary. ATEX and DNV-GL certified, the sensor can also be used in potentially explosive areas and features excellent mechanical strength. The ceramic sensor element is resistant to aggressive and abrasive media. The capacitive measuring principle enables a very accurate and long term stable measurement, even at lowest pressures and high overload resistance. The process connection is made of high-quality materials such as stainless steel 1.4404 or PVDF and is therefore suitable for almost all media. Our modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this data sheet.
Features
Front flush dry ceramic sensor
Smallest measuring range: 0…30 mbar
Largest measuring range: 0…40 bar
Negative pressure measuring range: up to -1 bar
Accuracy ≤ 0,2%
High overload capability
Rugged design
Optionally in plastic PVDF
Analog output: 4…20 mA, 2-wires
0…10 V, 3-wires
DNV-GL certified
Ex II 1G Ex ia IIC T4 Ga
I M2 Ex ia I Mb
Applications:
Viscous and pasty media
Hygiene applications
Gaseous media
Liquid media
Abrasive media
Aggressive media
Potentially explosive areas
Technical data:
- Negative pressure measuring range: up to -1 bar
Analog output - 4…20 mA, 2-wires
- 4…20 mA, 2-wires, II 1G Ex ia IIC T4 Ga
- 0…10 V, 3-wires
Power supply - 20 mA output: 9…30 V DC
- 10 V output: 15…30 V DC
Accuracy - ≤ ± 0,2 % FS @ 25 °C