The plastic version of the P121 pressure transmitter is particularly suitable for media that lead to corrosion of stainless steel and thus to sensor failure. The capacitive measuring principle enables a very accurate and long-term stable measurement, even at lowest pressures and high overload resistance. Our modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this data sheet.
Features
PP (Polypropylene)
Chlorine and salt water resistant
Smallest measuring range: 0...40 mbar
Largest measuring range: 0...40 bar
Negative pressure measuring range: up to -1 bar
Accuracy ≤ 0,2%
High overload capability
Analog output: 4…20 mA, 2-wires
0…10 V, 3-wires
Applications:
Salt water applications
Technical data:
- Negative pressure measuring range: bis -1 bar
- 0…10 V, 3-wires
Power supply - 20 mA output: 9…30 V DC
- 10 V output: 15…30 V DC
Accuracy - ≤ ± 0,2 % FS @ 25 °C
- ≤ ± 0,5 % FS @ 25°C ≤ 60 mbar
Long term stability - ≤ ± 0,15 % FS / Year
Response time - 200 ms - others on request
Switch-on time - < 1 s
Temperature coefficient - Zero: ≤ ± 0,015 % FS / Kelvin
- Span: ≤ ± 0,01 % FS / Kelvin
Medium temperature - -40…100 °C (125 °C < 0,5 h)
Surrounding temperature - -25…80 °C
Storage temperature - -40…85 °C
Short-circuit resistance - Permanent
Reverse polarity protection - Protection against reverse polarity, but no function
Electromagnetic compatibility - Interference emissions and immunity acc. to EN 61326
Vibration - 4g with 3-axis resonance frequency according to DIN EN 60068-2-6:2008