The P136 sensor is designed for use in applications where media tend to deposit and clog the sensor. A front-flush process connection prevents hidden edges and drill holes, in combination with a resistant ceramic sensor, optimal cleaning and maintenance can be ensured. The measuring range can be fine-tuned subsequently and the cable is connected directly to the integrated clamps. The ceramic sensor element is resistant to aggressive and abrasive media. The capacitive measuring principle enables a very accurate and long term stable measurement even at lowest pressures and high overload resistance. The process connection is made of high-quality stainless steel 1.4404 and is therefore suitable for almost all media. Our modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this data sheet.
Features
Front flush dry ceramic sensor
Dry capacitive ceramic sensor
Adjustable range (Turndown) 5:1
Smallest measuring range: 0…10 mbar
Largest measuring range: 0…60 bar
Negative pressure measuring range: up to -1 bar
Accuracy ≤ 0,2%
High overload capability
Rugged design
Analog output: 4…20 mA, 2-wires
Applications:
Viscous and pasty media
Hygiene applications
Aggressive media
Abrasive media
Technical data:
- Negative pressure measuring range: up to -1 bar
Analog output - 4…20 mA, 2-wires
Power supply - 20 mA output: 9…30 V DC
Accuracy - ≤ ± 0,2 % FS @ 25 °C
Response time - 200 ms - others on request
Switch-on time - < 1 s
Temperature coefficient - Zero: ≤ ± 0,015 % FS / Kelvin
- Span: ≤ ± 0,01 % FS / Kelvin