Magnetic-inductive flow meter OPTIFLUX 2000
volumefor waterfor wastewater

Magnetic-inductive flow meter - OPTIFLUX 2000 - JUMO GmbH & Co. KG - volume / for water / for wastewater
Magnetic-inductive flow meter - OPTIFLUX 2000 - JUMO GmbH & Co. KG - volume / for water / for wastewater
Add to favorites
Compare this product

Characteristics

Technology
magnetic-inductive
Type
volume
Fluid
for water, for wastewater
Pipe diameter
DN25 - 1", DN300 - 12"
Material
polypropylene
Communication
4-20 mA, analog output, with pulse output, HART
Protection level
IP67, IP68, IP66
Other characteristics
high-accuracy, with display, with LCD display, high-temperature
Process temperature

Min.: -273 °C
(-459.4 °F)

Max.: 90 °C
(194 °F)

Precision

0.5 %

Description

Overview
The OPTIFLUX 2000 is an electromagnetic flowmeter (EMF) engineered for water and wastewater applications. It is available with multiple drinking-water approvals and offers a wide dynamic measuring range for accurate flow measurement in DN 25 to DN 300 pipelines.

Highlights
  • Compliant with potable water standards
  • Wear- and maintenance-free measuring principle
  • Wide dynamic measuring range for stable readings

Technical data (table)
Measuring principle: Magnetic-inductive
Nominal widths: DN 25 to DN 300
Accuracy: 0.5 % of measured value
Medium temperature: Up to 90 °C
Process connection: PN 40 (DN 25–80), PN 16 (DN 100–150), PN 10 (DN 200–300)
Lining: PP, hard rubber
Ambient temperature: Up to 65 °C
Protection type: IP66/IP67, IP68 for remote version
Outputs: Analog (4 to 20 mA) with HART and pulse/frequency/status
Display: LCD with white backlight, shows up to 3 measured values
Special features: Drinking water approvals — ACS, DVGW, KTW, WRAS, NSF, KIWA

Technical specifications
  • Measuring principle: Magnetic-inductive
  • Nominal widths: DN 25 to DN 300
  • Accuracy: 0.5 % of measured value
  • Medium temperature: Up to 90 °C
  • Process connection: PN 40 (DN 25–80), PN 16 (DN 100–150), PN 10 (DN 200–300)
  • Lining: Polypropylene (PP), hard rubber
  • Ambient temperature: Up to 65 °C
  • Protection type: IP66/IP67 (IP68 for remote version)
  • Outputs: 4–20 mA with HART; pulse/frequency/status outputs
  • Display: LCD with white backlight (up to 3 measured values)
  • Drinking water approvals: ACS, DVGW, KTW, WRAS, NSF, KIWA

Catalogs

No catalogs are available for this product.

See all of JUMO GmbH & Co. KG‘s catalogs

Other JUMO GmbH & Co. KG products

Temperature

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.