Product informationNitrogen generator NITROBERG® 600
4.0 Nm3/h (99.99%)
Performance table (Capacity / Compressed air requirements)Nitrogen content | 97% | 98% | 99% | 99.5% | 99.9% | 99.99% | 99.995% | 99.999%
Capacity (Nm3/h) | 19.3 | 15.5 | 12.8 | 11.2 | 7.4 | 4.0 | 3.1 | 2.2
Compressed air factor | 2.3 | 2.3 | 2.6 | 2.9 | 3.4 | 4.6 | 5.2 | 6.4
Compressed air (Nm3/h) | 44.3 | 35.6 | 33.2 | 32.4 | 25.1 | 18.2 | 15.9 | 13.8
Compressed air (m3/h) * | 47.5 | 38.2 | 35.7 | 34.7 | 26.9 | 19.5 | 17.1 | 14.8
OverviewBERG NITROBERG® PSA nitrogen generators provide on-site nitrogen supply with selectable purities from 97% up to 99.999%. Designed for continuous operation, they are suitable for food packaging and processing, freezing, storage and transport, laboratories and industrial processes that require a dedicated nitrogen source to reduce cylinder logistics and supply costs.
Features- PSA nitrogen generation technology with adjustable purity options (97% up to 99.999%).
- Compact footprint for integration into production or laboratory environments.
- Integrated filtration stages (inlet/outlet and optional activated carbon) to protect adsorbent material and deliver clean nitrogen.
- Low electrical power consumption for continuous operation.
- Delivered with product and compressed air vessels sized to the selected purity and capacity.
- Model: NITROBERG® 600
- Article number: 1020200600
- Dimensions (L x W x H): 630 x 930 x 1780 mm
- Maximum pressure: 11 bar
- Operating pressure: 8 bar
- Weight: 247 kg
- Noise level: 55–85 dB(A)
- Ambient temperature: +5 to +40 °C
- Electrical connection: 230 V, 50 Hz / 110 V, 60 Hz
- Power consumption: 150 W
- Protection class: IP54
- Filters (inlet fine: 0.01 µm, inlet activated carbon: 0.003 µm, outlet fine: 3–5 µm) — optional
- Reference conditions: 20 °C, 0 m altitude, 1.0133 bar atmospheric pressure, 70% relative humidity
NotesSome filtration and vessel configurations are optional. Performance values refer to standard test conditions; actual performance may vary with different operating parameters. Contact the manufacturer for performance data under specific site conditions.