TESTO flow meters
Volumetric flow rate: 0 m³/h - 3,000,000 m³/h
Process temperature: -20 °C - 850 °C
For continuous volume flow measurement in dry gases. Reliable, even under extreme operating conditions. FEATURES Continuous measurement of velocity and volume flow Double-sided ...
Paddlewheel flow meters are impeller-type insertion meters fitted directly into the pipeline to measure the flow rate of water being pumped through a system. Walchem ...
Volumetric flow rate: 0.5 l/h - 60 l/h
Process temperature: -20 °C - 100 °C
Process pressure: 0 Pa - 400,000 Pa
Corrosion-resistant materials Easy to install Easy measuring tube replacement Limit switch optional Flow meters perform different tasks in conditioning systems for gas analysis. The typically quite ...
Volumetric flow rate: 0.3 l/h - 100 l/h
Process temperature: -20 °C - 100 °C
Process pressure: 0 Pa - 1,000,000 Pa
... High safety standard Certain applications in fluid and gas analysis require additional safety precautions, including flow meters. Here it's particularly important to protect the clear measuring tube ...
Volumetric flow rate: 0.5 l/min - 750 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Body material - Transparent acrylic Connection material - Polypropylene, ABS ( on request ) Float material - Stainless steel Seal material - Silicone, FPM ( on request ) Thread connection - 1/2″ – 3/4″ – 1″ – 1 1/2″ – 2″ G depending ...
ELETTROTEC s.r.l.
Process temperature: 0 °C - 113 °C
Process pressure: 0 bar - 34.47 bar
... Differential Pressure Meters are kits designed to measure differential pressures on flow measurement valves and flow measurement orifices at an accuracy of +/- 5%. It consists of a dial ...
Volumetric flow rate: 0 l/min - 350 l/min
Process temperature: -40 °C - 140 °C
Process pressure: 0 bar - 16 bar
Magnetic Inductive Flowmeter (Flow Meter) - All Metal - Stainless Steel - MIM Measuring range: 0.03 - 3 l/min ... 1.5 - 350 l/min liquids Accuracy: ±(0.8% of reading + 0.5% of FS) pmax: ...
KOBOLD INSTRUMENTATION
Volumetric flow rate: 0.8 l/min - 33,880 l/min
Process temperature: -29 °C - 71 °C
Process pressure: 10, 7 bar
The Tucor Ultrasonic Flow Meter Assembly (“UFM-A”) is a flow meter for the modern age of irrigation, with a design optimized for retrofit. Capable of measuring ultra-low ...
Volumetric flow rate: 0.8 l/min - 2,032.8 l/min
Precision: 2 %
... to unscheduled flow events. One featured product from our flow line, the Ultrasonic Flow Meter Master Valve Assembly (UFMV-A), is the ultimate tool for any retrofit ...
Process temperature: -20 °C - 60 °C
Precision: 0.4, 0.2 %
... electromagnetic flowmeter is completely autonomous with advanced functionality. Its benefits are flexible installation, high-precision volume measurement, and worldwide transmission of measured data via Modbus RTU protocol. ...
Arkon Flow Systems
Process temperature: -20 °C - 60 °C
Precision: 0.5 %
MAGE1 is an economic flowmeter with a carbon steel sensor and plastic transmitter that satisfies standard customer requirements. It is mains powered flowmeter (9-35 VDC) with 4-20 mA output, RS485 communication, ...
Arkon Flow Systems
... which can be freely installed and removed from the mainboard in seconds. Build your own flowmeter We offer you the possibility to customize to get the flowmeter according to your needs and your application. Plug ...
Arkon Flow Systems
Volumetric flow rate: 3 l/h - 50,000 l/h
Process temperature: 0 °C - 100 °C
Process pressure: 10 bar
... media, water, alkalines, acids Direct visualisation of the measured values Accuracy class 4 Integrated mounting rail for flow data sensors
Process temperature: -10 °C - 100 °C
Process pressure: 0.2 MPa
Precision: 0.5 %
These products are designed for environmental probe with integration of temperature and humidity sensors. The air flow is calibrated in a wind-tunnel. The products are designed for acquiring the environmental data ...
SIARGO
Process temperature: -10 °C - 55 °C
Process pressure: 1, 1.5 MPa
Precision: 1.5 %
MF5100 series mass flow meters are designed for a large dynamic range (200:1) and high accuracy of 1.5% of reading in flow metering and control applications. With Siargo's proprietary MEMS ...
SIARGO
Process temperature: -20 °C - 70 °C
Process pressure: 1 MPa
Precision: 1.5 %
MF5600 series mass flow meters are designed for general purpose flow metering and control applications where a detachable meter heat is required for some distance data ...
SIARGO
Volumetric flow rate: 0 m³/h - 140 m³/h
Process pressure: 16 bar
... rotating coupling • For horizontal or vertical installation • Robust water flow meter • Accurate meter measurements • Nominal diameter: DN 80 • Measuring error limit ±2 % ...
INTEGRA Metering AG
Process temperature: 0 °C - 50 °C
Process pressure: 16 bar
... measuring principle) • Robust water flow meter • Accurate meter measurements • Horizontal and vertical installation • Nominal diameter DN 40 • Protection class IP68 • SVGW ...
INTEGRA Metering AG
Process temperature: 0 °C - 50 °C
Process pressure: 16 bar
... principle) • Robust water flow meter • Accurate meter measurements Horizontal and vertical installation • Protection class IP68 • SVGW Certification • Stainless steel Storz ...
INTEGRA Metering AG
Volumetric flow rate: 0.9 m³/h - 9,048 m³/h
Process temperature: -10 °C - 85 °C
Precision: 0.5, 0.2 %
... able to process signals from fluids with flow rates of up to 10m / s in both directions (bidirectional meter). Reverse Flow - Allows measure and totalization of reverse flow Output ...
SGM LEKTRA
Volumetric flow rate: 0.1 m³/h - 18,000 m³/h
Process temperature: -40 °C - 100 °C
Precision: 0.5 %
Flow measurement for conductive liquids Measurement range DN10 ÷ 800 GPRS data transmission Battery powered, 6 years autonomy; 12÷24Vdc Analog, impulsive and MODBUS RTU outputs Parameter programming via ...
SGM LEKTRA
Volumetric flow rate: 1 m³/h - 9,048 m³/h
Process temperature: -40 °C - 85 °C
Precision: 0.5 %
... LEKTRA presents a new type of electromagnetic flowmeter with plastic sensors: RKmag. Because of its particular inner shape the mounting of the unit requires no straight pipe lengths before and after the meter. ...
SGM LEKTRA
Process pressure: 3.5 bar
Provides high reading accuracy of the operating pressure indicated on the internal scale (3.5 bar). The inner ball is easily visible and immediate reading is provided thanks to the presence of the two-colour silk-screen column (black ...
Volumetric flow rate: 1 l/min - 35 l/min
Process temperature: 50 °C
Process pressure: 0 bar - 100 bar
• The oval gear meter with electronic counter has been designed to measure motor oils (S.A.E. 5-50), gear oils (S.A.E. 80-240), transmission fluid, coolents (ethylene glycol), brake fluids and wiper fluids. ...
Dr. Jessberger GmbH
... quantities. As a result, the counter can be operated with pulse output in both flow directions, which is not possible by means of the display. The parameters of the display would sometime remain at zero ...
Dr. Jessberger GmbH
... can select his desired flow rate by means of a clearly structured and easy to use keypad. He can start the filling process immediately by a further keystroke and interrupt it any time. To ensures best dosing accuracy, ...
Dr. Jessberger GmbH
Volumetric flow rate: 5 m³/h - 2,400 m³/h
Process temperature: -40 °C - 200 °C
Process pressure: 0 bar - 200 bar
... is very suitable for opaque, corrosive or dangerous fluids used in most industrial processes. Its robust design enables the flow of viscous fluids or gases to be measured under particularly severe operating conditions. Indication ...
Volumetric flow rate: 0.1 m³/h - 250 m³/h
Process temperature: 60, 200, 150, 90 °C
Process pressure: 1.5 bar - 34.5 bar
... increases gradually. For a given flow rate, the float is established at a particular level where its weight is balanced with the pressure of the fluid. The upper flange of the float indicates the value of this flow ...
Volumetric flow rate: 0.2 m³/h - 200 m³/h
Process temperature: -40 °C - 200 °C
Process pressure: 6 bar - 16 bar
... For a given flow rate, the float is established at a particular level where its weight is balanced with the pressure of the fluid. The upper flange of the float indicates the value of this level on the graduated scale. Use The ...
Process temperature: 0 °C - 250 °C
Precision: 2 %
The DOPPLER flowmeters are designed to measure the volumetric flow in closed and full pipes. It consists of two sensors an emitter and an ultrasonic receiver. The emitted waves are transmitted by the ...
Sensotec Instruments
Process temperature: -10 °C - 80 °C
Precision: 1 %
Repeatibility: 0.2 %
Non-intrusive flowmeter for transit time for measurement of clean liquids. Electroinica mural with power to 220 Vac or 10/30 Vdc. Available with three types of sensors A (for pipes of 20 to 100 m), B (for pipes of 60 ...
Sensotec Instruments
Process temperature: 50 °C
High performance fixed installation Area Velocity flowmeter with extended features for open channel, part-filled pipe and river application. Dimensions: 166x161 x103 mm; Wall mounting ABS enclosure; Protection class: ...
Sensotec Instruments
Volumetric flow rate: 0.1 l/min - 150 l/min
Process temperature: 10 °C - 35 °C
Process pressure: 500,000 Pa
... indicates the flow rate. KOFLOC provides flow meters with a valve that can perform both measurement and control of the flow rate, flow meters ...
KOFLOC Corp.
Volumetric flow rate: 260 us gal/min - 52,000 us gal/min
Process pressure: 0 bar - 27.58 bar
... insertion flow meter that is intended to be retrofitted into an automatic control valve. It provides an accurate flow measurement data without installing a separate meter. ...
Process temperature: -40 °C - 70 °C
MULTIPHASE FLOW METERING Flowatch 3I The Pietro Fiorentini Multiphase and Wet Gas Flow Meters are non intrusive, inline systems providing real time measurement of oil, water and gas ...
PIETRO FIORENTINI
Process temperature: 150 °C
MULTIPHASE FLOW METERING Flowatch HS The Pietro Fiorentini Multiphase and Wet Gas Flow Meters are non intrusive, inline systems providing real time measurement of oil, water and gas ...
PIETRO FIORENTINI
Process temperature: 150 °C
... water and gas flow rates in Wetgas flow regimes (Lockhart-Martinelli < 0.3) without any separation or moving parts. It implements the latest state of the art technologies such as the Flow ...
PIETRO FIORENTINI
Volumetric flow rate: 1 m³/h - 4 m³/h
Process temperature: 50 °C
Process pressure: 0.3 bar - 16 bar
... starting flow and is permitted for all installation positions. The meter is equipped with an 8-digit glass/copper register (IP68) and a modulator disc. This enables electronic, non-reactive scanning ...
Process temperature: 120 °C
... signal is transmitted, once in the direction of flow and once against the direction of flow. The signal is accelerated in the direction of the volume flow and delayed against the direction ...
... series gas turbine flow meter is equipped with mechanical counter it’s a kind of meter don’t run slowly with high flow measurement accuracystrong anti-magnetic ...
Volumetric flow rate: 0.1, 0.2, 1 l/s
Process temperature: 0 °C - 50 °C
Process pressure: 7 bar
The ultrasonic flowmeter in beverage dispensing systems for alcoholic and nonalcoholic drinks. The contact-free flow measurement with no moving parts is wear and maintenance free. The free pipe cross-section ...
MIB GmbH Messtechnik & Industrieberatung
Volumetric flow rate: 0 l/min - 60 l/min
Process temperature: 0 °C - 50 °C
Process pressure: 7 bar
Flowmax 42i is a flow meter calculating the volume flow of liquids. Based on the ultrasonic technology Flowmax 42i is able to measure conductive and non-conductive liquids contactfree. ...
MIB GmbH Messtechnik & Industrieberatung
Volumetric flow rate: 0.3 l/min - 240 l/min
Process temperature: -10 °C - 80 °C
Process pressure: 10, 16, 15, 20, 25 bar
Flowmax 44i is a flow meter calculating the volume flow of liquids. MIB GmbH - Ultrasonic Flowmeter Flowmax 44iBased on the ultrasonic technology Flowmax 44i is able ...
MIB GmbH Messtechnik & Industrieberatung
Mass flow rate: 0.15 kg/min - 20 kg/min
Process temperature: -196 °C - 400 °C
Process pressure: 0 bar - 1,043 bar
... MATERIALS - 316Ti Alloy C22 Tantalum SuperDuplex more on request The RHM06 is a low risk, low maintenance solution for critical flow applications everywhere. High pressure and temperature options comined with a selection ...
Rheonik Messtechnik GmbH
Mass flow rate: 0.3 kg/min - 50 kg/min
Process temperature: -196 °C - 400 °C
Process pressure: 0 bar - 1,254 bar
... The Model RHM08 is perfect for small scale production with continuous low flow and small batch dispensing requirements. With a variety of construction styles, the RHM08 is ideal for countless flow ...
Rheonik Messtechnik GmbH
Mass flow rate: 0.75 kg/min - 100 kg/min
Process temperature: -196 °C - 400 °C
Process pressure: 0 bar - 1,097 bar
... SuperDuplex Tantalum more on request The RHM12 is a workhorse 1″ sensor used in every imaginable industry. Suitable for both continuous process and batching/filling applications, the RHM12 is a truly versatile tool ...
Rheonik Messtechnik GmbH
Process pressure: 2 MPa
... low activity, classified as exempted category by IAEA, combined with the venturi flow measurement technology to measure individual phase flow rate in a three-phase flow. Oil, gas and ...
Haimo Technologies Group Corp.
Volumetric flow rate: 6.3 l/min - 30 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0.2 bar - 10 bar
... air entry causing inaccurate measurements, the flow meter is sited upstream from the solenoid valve. The flow meter's output are pulses, where the frequency or the ...
Volumetric flow rate: 0 l/min - 3,000 l/min
Process temperature: -40 °C - 200 °C
Process pressure: 0 bar - 450 bar
Suco VSE France
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining