RTS-1 overviewRTS-1 is a compact personal bioreactor for aerobic and microaerophilic workflows. It applies patented Reverse-Spin® mechanical mixing in single-use 50 ml tubes and integrates near-infrared (NIR) optical monitoring for non-invasive, real-time tracking of cell growth kinetics.
Features- Reverse-Spin® mixing in 50 ml Falcon tubes achieves high kLa (up to 450 h-1) suitable for efficient aerobic cultivation
- Individually controlled unit accelerates process optimization and parallel testing
- Supports cultivation of microaerophilic and obligate anaerobic strains (not for strict anaerobic containment)
- Reverse-Spin® enables non-invasive biomass measurement in real time
- Near-infrared optical system (NIR) records growth kinetics without sampling
- Free software for real-time data storage, visualization and analysis
- Compact, low-profile design for benchtop or personal-lab use
- Temperature control and active cooling for rapid setpoint changes and stress experiments
- Task profiling and cycle definition for process automation
- Cloud data storage and remote monitoring via mobile device or PC
Software features- Real-time cell growth logging
- 3D graphical representation of OD or growth rate over time per unit
- Pause, Save/Load and reporting (PDF, Excel)
- Connect up to 10 units simultaneously to one computer
- Remote monitoring option (internet connection required)
- Cycling/profiling options and user-defined calibration for most cell types
Typical applications- Fermentation real-time growth kinetics
- Clone candidate screening
- Protein expression monitoring
- Temperature stress and fluctuation experiments
- Media screening and optimization
- Growth characterization
- Inhibition and toxicity testing
- Strain quality control
Technical specifications- Measurement range: 0–10 OD at 10–20 ml volume (0–19 OD λ600 nm equivalent)
0–8 OD at 20–30 ml volume (0–15.2 OD λ600 nm equivalent) - Measurement precision: ±0.3 OD
- Light source: near-infrared (NIR) light diode
- Measurement wavelength (λ): 850 nm
- Measurement periodicity: 1–60 readings per hour
- Culture volume: 10–30 ml
- Temperature setting range: +25°C … +70°C
- Temperature control range: ambient +5°C … +70°C
- Temperature stability: ±0.1°C
- Display: LCD
- Speed control range: 50–2,000 rpm
- Max units per software: 10
- Tube type for aerobic cultivation: 50 ml tube with membrane filter (TubeSpin® Bioreactor 50, TPP®)*
- Tube type for anaerobic cultivation: same as above; other manufacturer tubes of the same type may be used (rotor modification may be required)
- Minimum PC requirements: Intel/AMD processor, 1 GB RAM, Windows 10/11, USB 2.0
- Optimal PC requirements: Intel/AMD processor, 3 GB RAM, Windows 10/11, USB 2.0
- Overall dimensions (W×D×H): 130 × 212 × 200 mm
- Weight: 1.7 kg
- Input current/power consumption: 12 V, 3.3 A / 40 W
- External power supply: Input AC 100–240 V, 50/60 Hz; Output DC 12 V