OverviewModular receiving unit for AC power supply designed for industrial remote control applications. Configurable outputs, standard internal antenna with optional external antenna, and 16 inputs for data feedback. Five expansion slots accommodate programmable relay boards, voltage/current analog output boards, digital/analog input boards, variable resistive output boards, synchronization (Synchro) modules and serial communication boards (RS-232/485, CANopen, Profibus DP, PROFINET, EtherCAT®, EtherNet/IP™).
Technical data sheetPower supply: 24-230 VAC
Antenna: Internal standard; External optional
Max number of outputs: 40 on/off + START & STOP
Commands rated current: 6 / 10 A (250 VAC)
STOP / Safety outputs rated current: STOP 6 A (250 VAC); Safety 10 A (250 VAC)
Safety performance of the STOP function (EN ISO 13849-1): up to PL d
Protection degree: IP65 (NEMA 4)
Operating temperature: -20°C to +70°C (-4°F to +158°F)
Storage temperature: -40°C to +70°C (-40°F to +158°F)
Connecting interfaces: Cable gland; 24 or 32-pin plug
Dimensions: 185 x 287 x 105 mm (7.28 x 11.30 x 4.13 in)
Weight: 2.2 kg (4.9 lb)
Features / technical specifications- Model: ACRM5E
- Power supply: 24-230 VAC
- Antenna: internal standard; external optional
- Data feedback inputs: 16 inputs
- Expansion slots: 5 (for relay, analog output, digital/analog input, resistive output, sync, serial communication boards such as RS-232/485, CANopen, Profibus DP, PROFINET, EtherCAT®, EtherNet/IP™)
- Max outputs: 40 on/off + START & STOP
- Commands rated current: 6 / 10 A (250 VAC)
- STOP / Safety outputs rated current: STOP 6 A (250 VAC); Safety 10 A (250 VAC)
- Safety performance (STOP): up to PL d (EN ISO 13849-1)
- Protection degree: IP65 (NEMA 4)
- Operating temperature: -20°C to +70°C (-4°F to +158°F)
- Storage temperature: -40°C to +70°C (-40°F to +158°F)
- Connecting interfaces: cable gland; 24 or 32-pin plug
- Dimensions: 185 x 287 x 105 mm (7.28 x 11.30 x 4.13 in)
- Weight: 2.2 kg (4.9 lb)