Pressure calibration pressure controller Additel ADT793
digitalIP20precision

Pressure calibration pressure controller - Additel ADT793 - AOIP - digital / IP20 / precision
Pressure calibration pressure controller - Additel ADT793 - AOIP - digital / IP20 / precision
Pressure calibration pressure controller - Additel ADT793 - AOIP - digital / IP20 / precision - image - 2
Pressure calibration pressure controller - Additel ADT793 - AOIP - digital / IP20 / precision - image - 3
Pressure calibration pressure controller - Additel ADT793 - AOIP - digital / IP20 / precision - image - 4
Pressure calibration pressure controller - Additel ADT793 - AOIP - digital / IP20 / precision - image - 5
Add to favorites
Compare this product

Characteristics

Applications
for pressure calibration
Other characteristics
digital, IP20, precision, high-accuracy, adjustable, electronic
Pressure

Min.: 0 bar
(0 psi)

Max.: 1,000 bar
(14,503.77 psi)

Description

Overview
The Additel ADT793 pressure controller combines advanced control/measurement technology, a modular design and user-friendly maintenance features in a single industrial instrument. The ADT793 provides pressure control up to 1,000 bar and supports automated production, test and calibration workflows. It accepts a dual-range ADT151 pressure module and an optional barometric module to cover a wide pressure range quickly.

Key features
  • Maximum control range up to 1,000 bar
  • Interchangeable pressure modules (replacement in ≈30 seconds)
  • Oil and water versions available
  • Available accuracies: 0.02% FS, 0.01% FS or 0.01% RD
  • Dual-range option: -1 ~ 200 bar to 0 ~ 1,000 bar
  • Typical control stability 0.003% FS (≤ 0.005% FS)
  • Ultra-high speed pressure generation and control (typical response ≤ 30 s)
  • No external pressure source required (integrated hydraulic pump)
  • Control via internal or external pressure modules
  • Optional contamination prevention system (CPS)
  • LAN, USB, RS232 and Ethernet communication; extendable via USB to Wi‑Fi, Bluetooth, GPIB
  • External reservoir support
  • Easy maintenance with modular design
  • Emulation mode and SCPI command set compatible

Functional details and applications
Application: ADT793
Quick-change pressure modules (30 s): ADT151 modules can be installed or replaced quickly by opening the cabinet door; five module ranges are available (1000 bar, 700 bar, 400 bar, 350 bar or 200 bar) with multiple accuracy levels to meet application requirements.
External reservoir support: Design supports a contamination prevention method where the controller draws only clean fluid each cycle and purges potentially contaminated fluid externally to avoid cross-contamination between the controller and units under test (UUT).
Contamination Prevention System (CPS): Optional feature that facilitates maintenance by automatically draining fluids and performing purges between cycles to reduce contaminant introduction and improve durability and reliability.

Pressure specifications (excerpt)
Pressure range: 0 to 1,000 bar
Accuracy: 0.02% FS or 0.01% FS or 0.01% RD
Control stability: < 0.005% FS, typically 0.003% FS
Control response time (typical): < 30 seconds
Pressure type: gauge, absolute (absolute pressure requires optional ADT151-BP barometric module)
Internal pressure control modules: 1
External pressure control modules: 1
Maximum internal module range: 0 ~ 1,000 bar
Minimum internal module range: 0 ~ 200 bar
Minimum external module range: 0 ~ 70 bar
Range switching mode: Fixed, Automatic (does not support automatic switching between internal and external module)
Pump source type: Integrated hydraulic pump (no external source required)
Control modes: Fast, Standard, Custom
Maximum overshoot: < 1% FS
Maximum test volume: <700 bar: Max 80 ml (50 ml recommended); 700 ~ 1000 bar: Max 60 ml (35 ml recommended)
CPS system: Optional
Pressure port: 1/4 BSP M
Integrated reservoir volume: 800 ml
External reservoir extension: Optional
Port filters: Optional (all installed ports with 40 ~ 100 μm filters)
Media: Diethylhexyl sebacate or demineralized water

General specifications (excerpt)
Power: AC 100 ~ 240 V, 50/60 Hz
Fuse: T3.15 A 250 V AC
Maximum power consumption: 150 W
Chassis size: 440 (W) × 133 (H) × 380 (D) mm
Rack mounting dimensions: 3U-19" rack, horizontal orientation
Chassis weight: 20.7 kg
Pressure module weight: 0.4 kg
Operating environment: 10 °C ~ 50 °C
Storage temperature: 5 °C ~ 70 °C
Operating humidity: 5% RH ~ 95% RH non-condensing
Operating altitude: < 2000 m
Ingress protection: IP20 (indoor use)
Vibration level: 2G; Shock resistance: 4G
Warm-up time: 15 minutes
Compliance: CE, UKCA
Communication: RS232, USB-A ×2, LAN; extendable via USB to Wi‑Fi/Bluetooth/GPIB modules
SCPI command set: Compatible (configurable for compatibility with ADT780, PACE5000/6000, DRUCK DPI520...)
Display: 7" capacitive touchscreen, 1280 × 800 resolution, selectable black/white background; communication update rate: 10 times/s; display refresh rate: 5 times/s; max pressure display: +9999999 (adjustable resolution)

Modules and accessories
ADT151 pressure modules (examples): ADT151-XX-GP15K (0~1000 bar / 0~400 bar), ADT151-XX-GP10K (0~700 / 0~350 bar), ADT151-XX-GP6K (-1~400 / -1~200 bar).
High-precision module specifications 0.01% reading or 0.005% FS (worst case): models ADT151-01RD-GP15KM, ADT151-01RD-, ADT151-01RD-CP5KM, ADT151-01RD-CP3KM covering various gauge/absolute ranges.
Barometric modules: ADT151-BP (60~110 kPa ±22 Pa) and ADT151-BPH (±10 Pa tolerance).

Technical characteristics / specifications
  • Model: ADT793
  • Brand: Additel
  • Main range: 0 to 1,000 bar
  • Available accuracies: 0.02% FS, 0.01% FS, 0.01% RD
  • Control/stability: typ. ≤ ±(0.003 ~ 0.005) % FS
  • Typical stabilization time: < 30 s (20% step in 30 s)
  • Pump: integrated hydraulic (no external source required)
  • Integrated reservoir: 800 ml; external reservoir support: optional
  • Ports: 1/4 BSP M
  • Recommended test volume: <700 bar: 50 ml recommended; 700~1000 bar: 35 ml recommended
  • Port filtration: 40 ~ 100 μm (installed)
  • Compatible media: diethylhexyl sebacate or demineralized water
  • Interfaces: RS232, USB-A×2, LAN; extendable USB→Bluetooth/Wi‑Fi/GPIB
  • Display: 7" touchscreen 1280×800
  • Power: 100–240 VAC, 50/60 Hz; max consumption 150 W
  • Dimensions / weight: 440×133×380 mm; 20.7 kg
  • Environment: operating 10–50 °C, storage 5–70 °C, IP20
  • Compliance: CE, UKCA
  • Options: CPS contamination prevention system, interchangeable ADT151 modules, ADT151-BP/BPH barometric modules, accessories and calibration kits

Catalogs

No catalogs are available for this product.

See all of AOIP‘s catalogs

Other AOIP products

Calibration measurement - Pressure

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.