OverviewThe BBDM-2MR2M is an externally mounted ultrasonic transducer for non-contact liquid level detection through tank walls. With a 2 MHz center frequency and a recommended measuring range of 0.03–2 m, it is suited to fuel and oil tanks, sealed vessels, vehicle and machinery tanks, and corrosive liquid applications where through-wall sensing is required.
Narrow-beam performanceThe transducer has a -3 dB half-power angle of 2.4° ±10%. The narrow acoustic beam increases sensitivity to alignment, wall thickness, curvature and coupling; small angular or contact deviations can displace the acoustic path from the liquid interface and affect measurement accuracy.
Main technical specifications- Model: BBDM-2MR2M
- Center frequency: 2 MHz ±5%
- Recommended range: 0.03–2 m
- Minimum impedance: 10 ohm ±20%
- Capacitance: 2300 pF ±20% at 1 kHz
- Operating voltage: peak voltage below 150 Vpp
- Operating temperature: -40 to +80 °C (aluminum/PI); -20 to +80 °C (nylon option)
- Pressure rating: up to 10 kgf / 1 MPa
- Beam characteristic: -3 dB half-power angle 2.4° ±10%
- Housing material: 2A12 aluminum alloy and PI; alternative: Nylon
- Protection rating: IP68
- Weight: 240 g ±5%
- Cable configuration: 5 m + 1 m
Available material and temperature configurationsTwo housing options are offered and must be ordered as separate configurations: 2A12 aluminum alloy with PI (operating temperature -40 to +80 °C) and a nylon housing option (operating temperature -20 to +80 °C). Confirm the selected housing and its temperature rating when ordering; do not mix ranges between options.
Coupling and electronicsBefore specifying installation and drive electronics, confirm tank-wall material, wall thickness, curvature and coatings, and select an appropriate coupling method for the actual liquid and sensing path. The 10-ohm minimum impedance presents a different electrical load than higher-impedance tank transducers; drive circuitry must remain below 150 Vpp. Confirm the termination and definition of the 5 m + 1 m cable arrangement with the project requirements.
Technical specifications- Model: BBDM-2MR2M
- Center frequency: 2 MHz ±5%
- Recommended range: 0.03–2 m
- Minimum impedance: 10 ohm ±20%
- Capacitance: 2300 pF ±20% at 1 kHz
- Operating voltage: peak < 150 Vpp
- Operating temperature: -40 to +80 °C (2A12 aluminium + PI); -20 to +80 °C (Nylon)
- Pressure rating: up to 10 kgf / 1 MPa
- Beam: -3 dB half-power angle 2.4° ±10%
- Housing: 2A12 aluminum alloy & PI; alternative Nylon
- Mounting: refer to product dimensional drawing
- Protection: IP68
- Weight: 240 g ±5%
- Cable: 5 m + 1 m