Hydrocarbon gas analyzer 700-GLEL
gasfor monitoring gas emissionsprocess

Hydrocarbon gas analyzer - 700-GLEL - ENVEA - gas / for monitoring gas emissions / process
Hydrocarbon gas analyzer - 700-GLEL - ENVEA - gas / for monitoring gas emissions / process
Add to favorites
Compare this product

Characteristics

Measured entity
gas, hydrocarbon gas
Application domain
for monitoring gas emissions, process
Measured value
concentration
Configuration
wall-mounted
Mode of use
automatic
Technology
flame ionization
Detector type
FID
Protection level
SIL 2

Description

Product overview
The 700-GLEL explosive limit level (LEL) analyzer continuously measures flammable hydrocarbon concentration in gas samples. It uses Flame Ionization Detection (FID) in a heated oven containing a burner and regulated air/hydrogen supply. Hydrocarbons are ionized in the flame, producing an electrical current between electrodes that is measured to calculate hydrocarbon concentration and LEL values.

Features and benefits
  • Measurement range 0–100% LEL full scale
  • Auto calibration and back-flush
  • Fast response: 90% of full scale within 1 second
  • Electronic flow control with proportional pressure controller
  • Heated sample system (optional internal heated pump)
  • Automatic fuel/air shut-off for safety
  • Comprehensive diagnostics and condition monitoring
  • Outputs: voltage, current, RS-232, TCP/IP, MODBUS

Options
  • Internal heated sample pump
  • Internal zero and span solenoid valves
  • Wall-mounted configuration

Main applications
  • RTO / RCO feed gas monitoring
  • Combustion safety monitoring
  • Turbine and generator feedback control
  • Process chemical gas analysis
  • Personnel safety monitoring

Technical information (table view)
  • Model: 700-GLEL
  • Detector: Flame Ionization Detection (FID)
  • Measurement range: 0–100% LEL
  • Response time: 90% full scale in 1 second
  • Detection limit / resolution: 0.10 ppm carbon
  • Repeatability: Better than 1% of full scale
  • Linearity: Better than 1% of full scale
  • Zero drift: <1% FS per year
  • Span drift: <5% FS per year
  • Flow control: Electronic proportional pressure controller
  • Sample flow rate: Typically 2.0 LPM (consult factory for other rates)
  • Sample temperature: Up to 191°C, non-condensing (HFID)
  • Ambient temperature & humidity: -20 to 60°C / <90% RH (non-condensing)
  • Dimensions & weight: 5¼ H x 19 W x 23 D (inches); ~50 lbs
  • Outputs & communications: Voltage, current, RS-232, TCP/IP, MODBUS

Approvals & certifications
  • CE Mark and ETL Listed – Conforms to UL STD 61010-1; Certified to CAN/CSA C22.2 STD No. 61010-1
  • Meets 1065 requirements
  • Certified to SIL2

Catalogs

No catalogs are available for this product.

See all of ENVEA‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Ecomondo 2026
Ecomondo 2026

3-06 Nov 2026 Rimini (Italy) Hall B8 - Stand 204

  • More information

    Other ENVEA products

    REGULATORY COMPLIANT EMISSIONS MONITORING SOLUTIONS - CEMS

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.