Short descriptionBenchtop low-speed centrifuge CF-T5A for laboratory sample separation. Max speed 5500 r/min, max capacity 2000 ml and max RCF 5310×g. Equipped with a brushless DC motor and bearings sourced from Europe.
Features- Brushless DC motor with European-sourced bearings for smooth operation and reduced maintenance.
- Microcomputer control with touch panel and LED display for accurate speed and time setting.
- Stainless steel centrifugal chamber: low vibration, low noise, durable and easy to clean.
- Built-in safety protections: overspeed protection, door interlock and imbalance detection; rotors suitable for high-temperature and high-pressure disinfection (autoclave).
- Proprietary airflow guide minimizes chamber temperature rise to protect sensitive samples.
Technical specifications- Model: CF-T5A
- Max speed: 5500 r/min
- Max RCF: 5310 × g
- Max capacity: 2000 ml
- Speed accuracy: ±50 r/min
- Time range: 0–99 min
- Power supply: AC 220V 50Hz / 110V 60Hz 15A
- Noise: ≤60 dB
- Dimension: 460 × 590 × 420 mm
- Weight: 45 kg
- Included safety features: overspeed protection, door interlock, imbalance protection; rotors autoclave-compatible
Rotor options- Swing rotor No.63 — 4×50/100 ml — Max speed 5000/5500 r/min — Max RCF 4390/5310 ×g — Tube Ø38×124 mm
- Swing rotor No.69 — 4×500 ml — Max speed 4000 r/min — Max RCF 3580 ×g — Tube Ø80×140 mm
- Swing rotor No.70 — 4×250 ml — Max speed 4000 r/min — Max RCF 3500 ×g — Tube Ø64×113 mm
- Swing rotor No.75 — 72×5 ml — Max speed 4000 r/min — Max RCF 2830 ×g — Tube Ø14×54 mm
- Swing rotor No.77 — 32×10/15 ml — Max speed 4000 r/min — Max RCF 2810 ×g — Tube Ø16×85–118 mm
- Swing rotor No.81 — 8×50 ml — Max speed 4000 r/min — Max RCF 2810 ×g — Tube Ø38×124 mm
- Swing rotor No.82 — 48×5 ml — Max speed 5000 r/min — Max RCF 2800 ×g — Tube Ø14×54 mm
- Swing rotor No.84 — 120×7 ml — Max speed 4000 r/min — Max RCF 3200 ×g — Vacuum blood collection tubes
- Swing rotor No.84 — 148×7 ml — Max speed 4000 r/min — Max RCF 3200 ×g — Immuno tubes
- Microplate rotor No.43 — 2×2×96 wells — Max speed 4000 r/min — Max RCF 2300 ×g — microplates
- Adaptor — 12×50 ml / 8×100 ml (used in 4×500 ml rotor) — Max speed 4000 r/min — Max RCF 3580 ×g
- Adaptor — 8×50 ml / 32×10 ml (used in 2×250 ml rotor) — Max speed 4000 r/min — Max RCF 3500 ×g
Safety and maintenance- Follow manufacturer instructions for rotor installation and balancing; inspect rotors regularly for wear or damage.
- Rotors can be disinfected by autoclaving (high temperature and pressure); clean chamber with appropriate disinfectants and avoid abrasive agents.