OverviewATEQ introduces the MF520, a differential micro-flow tester combining fast cycle times with precise leak measurement using differential pressure-drop and stable flow measurement.
Applications- Leak detection and flow control for valve seats
- Gearboxes
- Hydraulic components and motors
- Aerosol control and injectors
Features- Measurement ranges: 2 / 20 / 200 ml/min
- Measurement units: SI, USA (SAE) and custom units
- Ambient temperature and atmospheric pressure indication
- Measurement element fully integrated in a single module
- Compliance: ROHS
Communication format- RS232: printer, PC and memory modules
- RS232: intelligent RC5 remote control
- RS485: ATEQ network
Mechanical pressure regulation- Vacuum
- 5–50 kPa
- 20–400 kPa
- 500–900 kPa
- 500–1600 kPa
Electronical pressure regulation- Vacuum
- 1–10 kPa
- 5–50 kPa
- 20–200 kPa
- 50–500 kPa
- 100–1000 kPa
- 100–1600 kPa
- 100–2000 kPa
Measurement rangesFLOW MEASUREMENT- 2 ml/min — Accuracy: ±2.5% of flow + 0.002 ml/min — Max resolution: 0.001 ml/min
- 20 ml/min — Accuracy: ±2.5% of flow + 0.02 ml/min — Max resolution: 0.01 ml/min
- 200 ml/min — Accuracy: ±2.5% of flow + 0.2 ml/min — Max resolution: 0.1 ml/min
PRESSURE MEASUREMENT- All ranges — Accuracy: P + 2 digits — Max resolution: 0.1% of full scale
Interface & Indicators- Navigation keys
- 4-line LCD display
- Result indicator lights
Power & Environmental- External supply: 24 VDC / 1.6 A or 110–240 VAC
- Operating temperature: +10°C to +45°C
- Storage temperature: 0°C to +60°C
Options- 7 inputs / 5 outputs
- 2 pneumatic outputs for control of sealing connectors
- 6 × 24 V programmable outputs for external connection
- Electronic regulator
- Dual pressure
- High speed valve
- 2 analog outputs: current or voltage
- Fieldbus
TechnologyThe Mass Flow technology converts the mass of air passing through a laminar flow element into a leak value (e.g. cm3.atm/h). It handles parts with large leaks on-line without resetting, does not use heating elements (reduced sensitivity to contamination) and includes temperature compensation. Pneumatics support highly accurate measurement at test pressures up to 20 bar (300 psi).
FactsheetsDetailed MF520 features, performance and ordering information are available in the product factsheets and datasheets.
Technical specifications- Model: MF520
- Brand: ATEQ
- Weight: approx. 7 kg
- Dimensions (W×H×D): 250 × 150 × 360 mm
- Flow ranges: 2 / 20 / 200 ml/min (see flow measurement accuracies above)
- Pressure measurement: P + 2 digits accuracy, 0.1% FS resolution
- Mechanical regulation: Vacuum / 5–50 / 20–400 / 500–900 / 500–1600 kPa
- Electronic regulation: Vacuum / 1–10 / 5–50 / 20–200 / 50–500 / 100–1000 / 100–1600 / 100–2000 kPa
- External supply: 24 VDC/1.6 A or 110–240 VAC
- Operating: +10°C to +45°C — Storage: 0°C to +60°C
- Interface: navigation keys, 4-line LCD, result indicator lights
- Air supply: clean, dry air (apply ISO 8573-1)
- IO & control: 7 inputs / 5 outputs, 2 pneumatic outputs, 6 programmable 24 V outputs, 2 analog outputs, fieldbus support
- Options: electronic regulator, dual pressure, high speed valve