Features- Panel‑mount industrial keyboard with integrated alphanumeric layout
- IP67 waterproof and dustproof stainless steel construction
- Laser‑engraved legends; options for raised characters or braille dots
- Available in multiple languages and custom layouts
- Vandal‑resistant design with anti‑corrosion and anti‑explosion properties
DescriptionIP67‑rated stainless steel keyboard designed for panel (front) mounting in industrial, kiosk and outdoor environments. The unit resists water ingress, dust and contaminants and remains operational across a wide temperature range. Laser engraving ensures durable key legends; layout and language can be customized to customer requirements. Mounting screws provide secure installation in control panels and kiosks.
Advantages- Compact footprint: combined alphabetic and numeric keys for installations with limited space
- Front panel mount: easy installation and maintenance with front fixing screws
- Customisable: supports different key layouts, languages and symbols for automation, kiosk or defence uses
- Long service life: industrial‑grade components and >5 million key operations for extended uptime
Applications- Military and defence equipment
- Industrial machinery and control panels
- Public and outdoor kiosks
DimensionsFront panel: 176.0 mm x 115.0 mm
Export certificationRoHS, CE, FCC
Warranty12 months
Caractéristiques / spécifications techniques- Operating Temperature: -20 °C to +60 °C
- Storage Temperature: -30 °C to +70 °C
- Waterproof rate: IP67
- Shock resistance: 3 axis 150 m/s² -11 ms, IEC 60512-4
- Electronics: Industrial level
- Humidity Resistant: 100%
- Vibration resistance: 5 Hz - 200 Hz, IEC 60512-4
- Actuation Force: 1.0 N ±0.1 N
- Key Travel: 1.5 mm
- Key switch Lifetime: 5 million operations
- Lifespan: > 3 years
- MTBF: > 50000 H
- MTTR: < 30 min
- G.W.: approx. 1.0 KGs
- Supply Voltage: +5V DC ±5%
- Current Rating: approx. 30 mA
- EMC Emission: EN55022(B)
- Saline mist: 96 hours, IEC 60512-6
- Damp heat test: at +40 °C: 21 days, IEC 60512-6
- Dry heat test: at +85 °C: 10 days, IEC 60512-6
- Operating Systems: Windows 95/98/NT/ME/2000/2003/XP/Vista/7/8/10, Linux, Unix, Mac OSX, VxWorks, Android