Product descriptionnetTAP 100 is an industrial gateway for deterministic protocol conversions between CANopen and PROFIBUS DP as well as between fieldbus and serial automation protocols. It supports conversions between a Real-Time Ethernet protocol (2-port) and a fieldbus or serial protocol, between two fieldbuses, or between a fieldbus and a serial protocol. Licensed Master functionality is available without restrictions. The device includes a memory card slot for storing firmware and configuration: a faulty unit can be restored within seconds by moving the card to a spare unit.
Features / Highlights- Integrates a subordinate CANopen network trunk into PROFIBUS and vice versa
- Master for up to 126 CANopen nodes or 125 PROFIBUS slaves
- I/O data conversion cycle typically below 10 ms
- Device exchange in seconds by loading via memory card
- Loadable firmware enabling additional conversion variants
- Diagnosis and configuration via USB interface
Supported protocols- CANopen Master
- PROFIBUS DP Master
- PROFIBUS DP Slave
- CANopen Slave
Technical specifications- Product name: NT 100-CO-DP
- Part number: 1716.180
- Brief description: Gateway CANopen to PROFIBUS DP
- Communication controller: netX (netX 100)
- RAM: 8 MB SDRAM
- FLASH: 4 MB serial Flash
- Memory card: SD or MMC card, max. 2 GByte
- Supply voltage: 24 V DC ± 6 V
- Maximum current at 24 V (typical): 130 mA
- Typical power consumption: 3.2 W
- Power connector: Mini-COMBICON, 2-pin
- Reverse voltage protection: yes
- Requirement for power supply (UL): device must be supplied by an isolated voltage source for UL-compliant usage
- Communication interface X2: CANopen; ISO 11898, optically isolated; connector D-Sub, plug, 9-pin
- Communication interface X3: PROFIBUS-DP; RS-485, optically isolated; connector D-Sub, socket, 9-pin
- Diagnostic interface: USB; Mini-USB, 5-pin
- Displays (LED): SYS, APL, CAN status (duo red/green), COM status (duo red/green)
- Operating elements: Network address (2 rotary switches)
- Ambient temperature (operation): 0 … +60 °C
- Humidity: no condensation permitted
- Pollution degree (UL): use in pollution degree 2 environment for UL compliance
- Altitude: 0 … 2000 m
- Dimensions (L x W x H): 100 x 52 x 70 mm (without connector)
- Weight: approx. 150 g
- Degree of protection: IP 20
- Mounting: on DIN rail EN 60715
- Configuration software: SYCON.net
- RoHS: Yes
- UL certification: UL 508 certified; UL-File No E334100
- EMC / Conformance: CE, UKCA; Emission: CISPR 11 Class A; Immunity: EN 61131-2; ESD (air): ±8 kV Criterion A; ESD (contact): ±4 kV Criterion A; Fast transient (Burst): ±2 kV Criterion A; Surge (communication/data lines): ±1 kV Criterion A