OverviewPA-TS-LWD is a high-performance laser particle size analyzer offering a wide dynamic range, strong repeatability and high accuracy for wet and dry measurements. It integrates advanced optical, mechanical and software systems to deliver reliable particle size distributions for industrial R&D and QC environments.
UsageSuitable for wet-dispersed samples and for powders requiring dry dispersion. Configurable sampling systems support routine laboratory analysis and on-demand production checks.
Working principleParticle size distribution is determined from scattered light energy using full-range Mie scattering theory. The instrument combines optimized optics, precise mechanics and signal processing to ensure fast, repeatable and traceable results.
Technical indicators- Measuring range: 0.02–2000 μm (wet), 0.1–2000 μm (dry)
- Measuring principle: full-range Mie scattering theory
- Repeatability error: ≤ 0.5% (standard sample D50)
- Accuracy error: ≤ ±1% (standard sample D50)
- Measurement speed: typical measurement ≤ 10 seconds
- Injection method:
- Wet: high-power precision centrifugal pump, stirring up to 4000 rpm, built-in ultrasound, stepless adjustment
- Dry: dispersion range 0.1–2000 μm, working pressure 0.05–0.6 MPa stepless, injection speed 0–100% stepless
- Optical system: dual light source (He–Ne 0.6328 μm + blue semiconductor 0.466 μm), laser fluctuation < 0.5%, folding closed path, single-lens Fourier transform structure
- Detector: 98 channels; detection angle range 0.016°–140°; 3D detection (forward/lateral/back)
- Software: modular design, SOP support, AI-assisted self-test, multiple export formats, switchable distributions (volume, surface area, length, number)
Appearance sizeMain unit: 1115 × 254 × 355 mm
Loop sampler: 265 × 325 × 405 mm (SCF-108), 210 × 260 × 345 mm (SCF-105B)
Dry sampler: 305 × 245 × 295 mm (DPF-110)
Performance characteristicsAdvanced optical systemDual-light-source design improves resolution across nano to large particles by combining He–Ne and blue semiconductor wavelengths.
Stable laser light sourceShort warm-up, single-mode polarized laser, polarization ratio > 500:1, TEM00 > 95%, power fluctuation < 0.5% for low and stable background.
Folding light path designClosed folded optical path and high-precision aluminum optical platform reduce dust and ensure mechanical stability.
Single lens, Fourier transform structureMinimizes optical surfaces to reduce background noise and improve signal-to-noise ratio for small-angle detection.
Long focal length Fourier lensExtended effective focal length enables detection of very small scattering angles and reliable measurement of particles up to 2000 μm.
High-sensitivity imported photodetectorsCustom detectors with up to 98 channels provide comprehensive angular coverage and accurate scattered-light acquisition.
Intelligent automatic alignmentSoftware-controlled automatic alignment in seconds ensures repeatable optical positioning and measurement consistency.
Decentralized sample systemsWet injection: standard SCF-108 circulating sampler (high-power centrifugal pump, up to 4000 rpm, 100 W ultrasound, 1000 mL cell); optional SCF-105B fully automatic sampler (316L cell, 50 W bottom ultrasound).
Dry injection: standard DPF-110 dry sampler with adjustable dispersion pressure, built-in pressure sensors and contamination protection.
Powerful analysis software- Modular architecture and instrument status visualization
- SOP-driven workflows and clear navigation
- Multiple analysis models and switchable distribution outputs
- AI-assisted self-check, automatic sampling recognition and pre-measurement background measurement
- Multiple export formats and open sample parameter database
Technical specifications- Model / SKU: PA-TS-LWD
- Measuring range (wet): 0.02–2000 μm
- Measuring range (dry): 0.1–2000 μm
- Measuring principle: Mie scattering theory
- Repeatability error: ≤ 0.5% (D50)
- Accuracy error: ≤ ±1% (D50)
- Measurement speed: typical ≤ 10 s
- Wet injection: centrifugal pump, stirring ≤ 4000 rpm, built-in ultrasound
- Dry injection: dispersion pressure 0.05–0.6 MPa, injection speed 0–100% stepless
- Optical sources: He–Ne 0.6328 μm and blue semiconductor 0.466 μm
- Laser power fluctuation: < 0.5%
- Detector channels: 98; detection angle range: 0.016°–140°
- Main unit dimensions (L×W×H): 1115 × 254 × 355 mm
- Loop sampler dimensions: SCF-108 265 × 325 × 405 mm; SCF-105B 210 × 260 × 345 mm
- Dry sampler dimensions: DPF-110 305 × 245 × 295 mm