Product overviewThe MPRZA strain relief bushing secures and protects cables at panel entry points. It absorbs tensile, compressive and torsional loads and guides the cable with a 90° bend to keep it parallel and close to the structure, saving installation space.
Performance and useGood chemical resistance and electrical properties make the MPRZA suitable for standard industrial environments. In confined spaces the part can also serve as a protective bumper.
InstallationSnap-fit installation into panel holes. Available for round and flat cables. Two hole types are used depending on retention required:
- A: hole that allows the part to rotate.
- A × B: hole that fixes the part and prevents rotation.
AccessoriesRecommended installation tool: MHPA. Installation can alternatively be performed with pliers.
Product table (measures in millimetres)Reference | A | B | Max. panel thickness | L / L1 | Suitable for cable | Round cable | Flat cable | Cable type
00101000100 | 11,10 | 9,90 | 1,60 | 12,70 / 5,50 | 3,0 to 5,6 | ✓ | ✕ | SPT1
02001002105 | 11,10 | 9,90 | 1,60 | 12,70 / 5,90 | 3,0 x 5,6 | ✕ | ✓ | SPT1
02001002106 | 12,70 | 11,40 | 1,00 | 17,50 / 9,90 | 3,0 x 7,6; 3,8 x 7,1; 4,1 x 7,6 | ✕ | ✓ | SPT2 / HPN
00101000101 | 12,70 | 11,40 | 2,50 | 17,50 / 10,00 | 3,8 x 7,1; 4,1 x 7,6 | ✕ | ✓ | SPT2 / HPN
00101000102 | 12,70 | 11,40 | 2,50 | 17,50 / 10,00 | 6,4 to 6,7 | ✓ | ✕ | SV
02001002107 | 12,70 | 11,40 | 2,50 | 17,50 / 9,90 | 3,0 x 7,6; 3,8 x 7,1; 4,1 x 7,6 | ✕ | ✓ | SPT2 / HPN
02001002109 | 14,20 | 18,50 | 2,00 | 20,60 / 10,30 | Multiple | ✕ | ✓ | SPT2 / SPT3
02001002110 | 14,20 | 18,50 | 3,20 | 20,60 / 10,30 | Multiple | ✕ | ✓ | SPT2 / SPT3
00101000103 | 14,30 | 13,30 | 3,20 | 22,20 / 13,10 | Multiple | ✕ | ✓ | SPT2 / HPN / SPT3
02001002108 | 14,30 | 13,30 | 3,20 | 21,80 / 12,70 | Multiple | ✕ | ✓ | SPT2 / SPT3 / HPN
02001002101 | 15,90 | 14,00 | 3,20 | 24,60 / 14,30 | 7,6 to 8,4 | ✓ | ✕ | SJ / SJO / SJT
02001002102 | 15,90 | 14,00 | 3,20 | 24,60 / 14,30 | 8,3 to 9,0 | ✓ | ✕ | SJ / SJO / SJT
02001002103 | 19,00 to 19,80 | 16,80 | 3,20 | 27,70 / 16,30 | 9,1 to 10,9 | ✓ | ✕ | SJT / SJTO / SJ / ST
02001002111 | 19,90 | 22,20 | 3,20 | 23,80 / 12,30 | Multiple | ✕ | ✓ | SPT3
02001002104 | 22,20 | 20,70 | 3,20 | 34,50 / 21,40 | 13,5 to 14,2 | ✓ | ✕ | S
02001002112 | 22,20 | 21,30 | 3,20 | 24,60 / 12,70 | Multiple | ✕ | ✓ | SPT3
02001002113 | 28,00 | 25,40 | 3,20 | 36,50 / 18,60 | 8,0 x 16,8 | ✕ | ✓ | SPT3 / SRD / SRDT
Compliance and markingsUL94: V2 (self-extinguishing). RoHS: compliant. Measures expressed in millimetres.
Technical specifications- Model / family: MPRZA
- Material: PA66 (Polyamide 66)
- Colours: Black / White (other colours available on request for specified quantities)
- Operating temperature: -18 °C to +105 °C
- Flammability: UL94 V2, self-extinguishing
- Certifications: UR, CSA
- Design: 90° bend to keep cable parallel and close to structure
- Function: absorbs tensile, compressive and torsional forces; provides electrical and mechanical protection; can act as protective bumper in limited spaces
- Installation: snap-fit into panel holes; two hole types (A for rotation, A × B to prevent rotation)
- Suitable for: round and flat cables (see table for specific compatible cable sizes)
- Measures: expressed in millimetres