Product overviewExcelitas Noblelight NNILight low-pressure mercury UVC lamps are designed for germicidal disinfection of water, air and surfaces. Available in 800, 1000 and 1500 W nominal outputs, these lamps deliver primary germicidal emission at 254 nm; a synthetic quartz option provides additional 185 nm emission for oxidation processes.
Design and optionsNNILight lamps are offered in multiple arc lengths (10–150 cm) and formats including straight rods, U-shaped designs and several end-connector types. U-shaped variants provide a more compact footprint with increased output. Options include ozone-free and ozone-generating configurations depending on quartz type.
Performance detailsHigh-efficiency low-pressure designs yield elevated UVC output with typical UV efficiency at 254 nm of ~40% for conventional lamps and 25–35% for high-output variants. Synthetic quartz versions emit both 254 nm and approx. 185 nm (when specified) to support oxidation and odor removal where required.
Important handling note- Lamps contain mercury. Manage in accordance with local, state or federal disposal laws.
Features- Primary germicidal emission at 254 nm
- Synthetic quartz option for 185 nm vacuum-UV
- Available nominal outputs: 800 W, 1000 W, 1500 W
- Arc length range: 10–150 cm
- Formats: straight, U-shaped, various end connectors
Applications- Drinking water disinfection (municipal and industrial)
- Sewage treatment and wastewater applications
- Air disinfection in HVAC and hospital environments
- Grease and odor control in foodservice and commercial kitchens
- Reduction of pollutants in industrial exhaust air
Installation & maintenance guidanceInstallation must be performed by trained personnel to ensure correct electrical connections, alignment and ventilation. Maintain clean quartz sleeves to preserve UV transmission. Avoid frequent on/off cycling and verify cooling systems to extend electrode life. Carry out routine inspection of lamp surfaces, connectors and reflectors to sustain uniform output.
Safety measuresEnsure installation by qualified staff, provide appropriate shielding to prevent direct UVC exposure, follow electrical safety practices and dispose of lamps per applicable hazardous-waste regulations. Use protective equipment when servicing.
Specifications - Conventional low-pressure lampsOzone property | Ozone-free | Ozone-generating
Spectrum: Wavelength | 254 nm | 185 nm, 254 nm
Arc length | 10 – 150 cm | 10 – 150 cm
Electrical power | 5 – 80 W | 5 – 80 W
Typical UV efficiency at 254 nm | 40% | 40%
Typical efficiency at 185 nm, natural quartz glass | - | approx. 6%
Typical efficiency at 185 nm, synthetic quartz glass | - | approx. 9%
Specific UVC flux | 0.1 – 0.4 W/cm | 0.1 – 0.4 W/cm
Use at ambient temperatures | up to max. 40°C | up to max. 40°C
Service life | 9,000 h with 30% decline of UV intensity | 9,000 h with 30% decline of UV intensity
Specifications - High-output low-pressure lampOzone property | Ozone-free | Ozone-generating
Spectrum: Wavelength | 254 nm | 185 nm, 254 nm
Arc length | 10 – 150 cm | 10 – 150 cm
Electrical power | 10 – 150 W | 10 – 150 W
Typical UV efficiency at 254 nm | 25-35% | 25-35%
Typical efficiency at 185 nm, natural quartz glass | - | approx. 6%
Typical efficiency at 185 nm, synthetic quartz glass | - | approx. 9%
Specific UVC flux | 0.2 – 0.5 W/cm | 0.2 – 0.5 W/cm
Use at ambient temperatures | up to max. 60°C | up to max. 60°C
Service life | 9,000 h with 30% decline of UV intensity | 9,000 h with 30% decline of UV intensity
Technical specifications- Series: NNILight
- Available nominal outputs: 800 W, 1000 W, 1500 W
- Wavelengths: primary germicidal 254 nm; synthetic quartz option adds 185 nm (vacuum UV)
- Arc length range: 10 – 150 cm
- Electrical power ranges: conventional 5 – 80 W; high-output 10 – 150 W
- Typical UV efficiency at 254 nm: conventional ~40%; high-output 25–35%
- Typical efficiency at 185 nm (when applicable): natural quartz ≈6%; synthetic quartz ≈9%
- Specific UVC flux: conventional 0.1 – 0.4 W/cm; high-output 0.2 – 0.5 W/cm
- Ambient operating temperature: up to 40°C (conventional), up to 60°C (high-output)
- Service life: ~9,000 h with 30% decline of UV intensity
- Design options: straight rods, various end connectors, U-shaped lamps for compact higher output